Rectifying faults
FORMER 12545 PRO
59
Fault
Possible causes
Remedy
Swath width too big
Incorrect swath width setting
Adjust the swath width (see Sec-
tion 7.7.1 Adjusting the swath
width)
Drive speed too low
Increase the drive speed (guide
value 450 rpm)
Working width too wide
Adjust the working width (see Sec-
tion 7.7.2 Set working width).
Irregular directional stability
or considerable tire wear
Misalignment of transport
wheels
Have the alignment corrected at a
specialist workshop.
Hydraulic working width ad-
justment is jerky/uneven
Drive shaft sliding profiles are
sluggish
Pull apart the drive shaft, then
clean and lubricate the two halves.
The machine menus are not
being displayed
ISOBUS function on the tractor
terminal deactivated
Switch on the ISOBUS function
(see Operator's Manual for the
tractor or the ISOBUS terminal).
ISOBUS plug loose
Check the plug connection.
ISOBUS plug not connected
Insert the plug for the ISOBUS
control unit into the ISOBUS con-
nection on the tractor.
ISOBUS of the tractor open
Insert a dummy plug into the in-
cab socket (see Operator's Man-
ual for the tractor).
The "PTO shaft speed is too
high" warning message is dis-
played
The drive speed is too high
Decrease the drive speed. (guide
value 450 rpm)
Error code 200 is displayed
Sensor faulty or cable break
Have the sensor repaired by a
specialist workshop. Use the
"Manual Operation" menu to oper-
ate the machine. (see Section 9.2
Emergency operation)
Error code 201 is displayed
Loose plug connection
The error message tells you which
sensor is faulty. Check the plug
connections for the sensor. Select
the "Diagnostics" menu. Check
whether a value for the sensor is
displayed in the "Diagnostics"
menu.
If no value is displayed:
Have the sensor repaired by a
specialist workshop. Use the
"Manual Operation" menu to oper-
ate the machine. (see Section 9.2
Emergency operation)
No value on the hectare
counter
Speed signal cannot be found
Check the settings for the speed
signal in the "User Setup" menu.
Check the "travel speed" value in
the "Diagnostics" menu.
If no value is displayed, contact a
specialist workshop.