34
"
#
!
%
!
"
$
#
#
#
1
2
Edgebander
G 330 / G 360 / G 380
Inspecting and adjusting settings
Warning! Risk of burns and serious injuries!
Many parts of the machine are very hot, in particular the glue pot!
Use all suitable methods of protection to prevent severe injury.
8.5 Teflon coated changable gluepot
Switch the machine off and ensure that it cannot be swit-
ched on again Remove the machine from the compressed
air supply system and vent the remaining compressed air.
Open the rear access door.
Preparing to change the glue pot:
1.
Disconnect both pneumatic hoses.
!
2.
Loosen and remove the knurled screw
"
3.
Loosen and remove the securing bolt (3x
#
)
(Hexagon socket T-handle
$
)
4.
Remove the edge feeder
%
Note:
Create a safe place for the glue pot (so that cables
cannot be damaged and no glue can escape).
Remove the glue basin:
1.
Open the plug safety clamps.
Disconnect the power supply
!
2.
Loosen the glue pot clamp
"
3.
Screw the knurled screw into the glue pot.
#
4.
Pull the glue pot upwards and out:
1st hand pulls,
2nd hand holds the pot stable
5.
Place the glue pot in such a way that the glue cannot
run out.
Fitting in the glue pot:
To reassemble, follow the instructions in the reverse order.
Check the fitting:
Test
Plug in the power supply and close the safety clamps.
Connect both pneumatic hoses.
Fig. 8-7.1: Preparing to change the glue pot
Fig. 8-7.2: Remove the glue basin