54
&
"
#
%
!
!
$
Edgebander
G 330 / G 360 / G 380
!
Socket head cap screw
"
Flange
#
Saw blade
$
Rear flange
%
Allen key 8 mm
&
Spanner SW 10 mm
Fig. 10-10: Vacuum connector assembly
Warning! Risk of injury!/Risk of material damage!
Handle the saw blades carefully to avoid injuring your hands and damaging the cutting edges.
Fig. 10-11: Changing the tooling
!
Counter screw for the saw guard
10.5 Changing the saw blade - End trimming unit
Maintenance/Service
Respect the general safety rules.
See chapter entitled >10.1 Safety instructions<
Required tools:
• hex key 4 mm / 8 mm
• Spanner SW 10 mm
1.
Switch the machine off and ensure that it cannot be
switched on again
Remove the machine from the compressed air supply
system and vent the remaining compressed air.
Open the rear access door.
2.
Loosen the screws and remove the vacuum connector.
3.
Block the motor shaft with a 10 mm spanner and
loosen the mounting screw.
It is important to maintain the opposite position using
an allen key (8 mm)
4.
Remove the old saw blade and place the new saw
blade on the arbor. Note the direction of rotation!
5.
Replace the flange (take note of the assembling
position).
Secure the screw again.
minimum tightening torque: 20 Nm
6.
Position the vacuum hood correctly.
Tighten the socket head cap screws on both sides.
Note:
Once the tools have been changed:
Check the protruding edge of the saw blades or adjust.
See chapter entitled
>Inspecting and adjusting set-
tings<