Installation
UltraVoice (UV)
5. Attach the UV controller to the wall, using four user-supplied 1/2 inch x 5 inch lag
bolts. Slide a user-supplied 1/2 inch flat washer onto each bolt before threading
the bolt into the pole.
6. Install a user-supplied, fused, disconnect switch. Use the proper type required by
the authority having jurisdiction in your area.
7. If the speaker array is installed on the roof of the building, it may be desirable to
install the UV controller inside the building, if practical.
Figure 9 Typical Siren
REFER
TO
SPEC
REFER
TO
SPEC
MOD6024B
RADIO ANTENNA (YAGI)
SPEAKER CABLE IN CONDUIT
TELEPHONE POLE
ANTENNA CABLE
WITH MAIN DISCONNECT
BATTERY CABINET
CONTROL CABINET
GROUND RODS (2 EACH) 8' MIN.
120VAC SINGLE-PHASE METER BASE
(Must meet local utility requirements)
291164D