![background image](http://html1.mh-extra.com/html/federal-signal-corporation/ultravoice-uv/ultravoice-uv_installation-operation-and-service-manual_3830688028.webp)
28
Installation
UltraVoice (UV)
Activation Formats
For Two-Tone activated units, the Two-Tone Timing parameters configures the time
duration of the activation tone codes. The three parameters, A-Time, B-Time and S-Time;
sets the time duration for the A-tone, B-tone and Single-Tone respectively.
NOTE
: The Two-Tone timing parameters are minimum values only. The actual tone
times may be longer than the specified times.
• Single tone, two-tone, DTMF, MSK, EAS and POCSAG decoders for remote siren
control
• DTMF or MSK encoders for remote status monitoring
User Programs
The UV controller has the capacity to store up to fifty user programs. Each user program
contains
twenty
stacked function items.
Assigning more than one function to each activation code or user program allows you to
run a sequence of functions without sending additional activation commands.
Activation Functions
Table 16 Activation Functions
Function
Definition
Arm
Arms the siren.
Disarm
Disarms the siren.
Wail
Sound Wail siren tone.
Pulsed Wail
Sound Pulsed Wail siren tone.
Alternate Wail
Sound Alternate Wail siren tone.
Steady
Sound Steady siren tone.
Pulsed Steady
Sound Pulsed Steady siren tone.
Alternate Steady
Sound Alternate Steady siren tone.
Auxiliary (Chime)
Sound Auxiliary siren tone. The Auxiliary tone is normally set for
Westminster Chimes.
Digital Voice
(1-250 DV
messages)
Enter the desired digital voice number to run and click OK. If voice
number is not between 1 and 250, an error message box appears.
Dynamic Voice
Plays a sequence of digital voice messages specified at the time of
activation. This function is only applicable for sirens equipped with a
special vocabulary chip.
Public Address
Broadcast live radio PA. PA remains active until carrier has dropped
for ten seconds or 4 1/2 minutes, whichever occurs first.
Play Recorded PA Play message previously recorded during the “RECORD PA” function.
For EAS activation, the message repeats continuously for the duration
of time encoded in the TTTT field. For non-EAS activation, the “PLAY
RECORDED PA” function plays once without repeats.
Quiet Test
Performs a self-test of the siren’s amplifiers and speakers by sounding
a 20 kHz tone.
Содержание ultravoice UV
Страница 42: ...42 Installation UltraVoice UV Figure 15 Omni Antenna Installation Example...
Страница 43: ...43 Installation Installation Operation and Service Manual Figure 16 Antenna Grounding...
Страница 71: ...71 Appendix C Drawings Figure 25 UV Controller Two way Radio Wiring Diagram...
Страница 72: ...72 Figure 26 UVTD IP Broadband Wiring Diagram...