29
Installation
Installation, Operation, and Service Manual
Function
Definition
Cancel
Terminates active function.
Report
Send unit status to base.
Master Reset
Terminates active function and clears latched status.
Plus Phase
All functions between “PLUS PHASE” and “MINUS PHASE” repeat
for the duration of time encoded in the EAS activation frame (EAS
activations only).
Minus Phase
All functions between “PLUS PHASE” and “MINUS PHASE” repeat
for the duration of time encoded in the EAS activation frame (EAS
activations only).
Phase Off
Turn off minus and plus phase and return siren to omni directional
mode.
Low Power/
High Power
Causes the siren to operate at a greatly reduced volume level. Upon
activation of a user program, the siren defaults to High (normal)
volume level. This command must follow an ARM command. Reduced
volume mode remains in effect for all subsequent functions in a user
program that follow the Low Power function or until a High Power
function occurs or an ARM command is sent. The Low Power function
is one watt per amplifier.
Power
The Power function controls the volume level. You can adjust the
volume from 0 to -20 dB in 1 dB steps. Reduced volume mode
remains in effect for all subsequent functions in a user program that
follow the Power function, or until another Power function occurs, or
an ARM command is sent. NOTE: Each 3 db reduction results in half
the power output.
Delay
Causes the siren to pause (wait) for 2 to 500 seconds before
starting the next function of the user program currently running.
When selecting the delay function, the user is prompted to enter the
desired delay time in seconds. A default delay of 4 seconds is present
between functions, without adding a delay.
Amp/Audio Zone
Allows you to control which amplifiers are to operate.
The Amp/Audio Zone function allows you flexibility in building alerting
or other zone dependent systems. You can divide each UV controller
into eight different zones. When selecting the Zone Control function,
you are prompted to enable or disable each of eight possible zones,
corresponding to each amplifier in the siren. Upon activation of a user
program, the siren defaults to all zones enabled. The ZONE command
must follow an ARM command. Zoning remains in effect for all
subsequent functions in a user program that follows the zone function
or until another ZONE or ARM function occurs.
Record PA
Records live PA message for later playback using the “PLAY
RECORDED PA” function. Recording is terminated by reception of
the EAS-SAME End of Message command or two minutes, whichever
occurs first.
Zone A (rotating
sirens only)
Position siren head in the A direction.
Zone B (rotating
sirens only)
Position siren head in the B direction.
Содержание ultravoice UV
Страница 42: ...42 Installation UltraVoice UV Figure 15 Omni Antenna Installation Example...
Страница 43: ...43 Installation Installation Operation and Service Manual Figure 16 Antenna Grounding...
Страница 71: ...71 Appendix C Drawings Figure 25 UV Controller Two way Radio Wiring Diagram...
Страница 72: ...72 Figure 26 UVTD IP Broadband Wiring Diagram...