Maintenance - Every 250h
4812165801.pdf
2024-04-22
Battery
- Check condition
Fig. Batteries
The batteries are sealed and maintenance-free.
Make sure there is no open flame in the vicinity
when checking the electrolyte level. Explosive gas
is formed when the alternator charges the battery.
Make sure there is no open flame in the vicinity
when checking the electrolyte level. Explosive gas
is formed when the alternator charges the battery.
When disconnecting the battery, always
disconnect the negative cable first. When
connecting the battery, always connect the
positive cable first.
When disconnecting the battery, always
disconnect the negative cable first. When
connecting the battery, always connect the
positive cable first.
The cable shoes should be clean and tightened.
Corroded cable shoes should be cleaned and
greased with acid-proof Vaseline.
Wipe the top of the battery.
Air conditioning (Optional)
- Inspection
Inspect refrigerant hoses and connections and make
sure that there are no signs of an oil film that can
indicate a refrigerant leakage.
The refrigerant contains tracing liquid, which makes it
possible to detect leaks with the aid of a UV lamp. If
the areas around the connections are strongly
coloured, this is an indication of a leak.
Automatic Climate Control (Optional) -
Inspection
Fig. Engine compartment, left side
1. Sight glass
2. Drying filter
1
2
Open the left-hand engine compartment door with the
unit in operation and check using the sight glass (1)
that bubbles are not visible on the drying filter.
The filter is located on the rear frame on the outer
edge of the engine compartment. If bubbles are visible
through the sight glass, this is a sign that the
refrigerant level is too low. If so, stop the unit. The unit
may be damaged if it is run with insufficient refrigerant.
132
Содержание DYNAPAC CX8
Страница 2: ......
Страница 12: ...e 4812165801 pdf 2024 04 22 Compressor Replacing V belt 166...
Страница 16: ...Introduction 4812165801 pdf 2024 04 22 4...
Страница 36: ...Technical specifications 4812165801 pdf 2024 04 22 24...
Страница 46: ...Machine description 4812165801 pdf 2024 04 22 4812129673 Warning CALIFORNIA Proposition 65 34...
Страница 72: ...Machine description 4812165801 pdf 2024 04 22 60...
Страница 110: ...Operation 4812165801 pdf 2024 04 22 98...
Страница 140: ...Maintenance Every 10h 4812165801 pdf 2024 04 22 128...
Страница 142: ...Maintenance Every 50h 4812165801 pdf 2024 04 22 130...
Страница 146: ...Maintenance Every 250h 4812165801 pdf 2024 04 22 134...
Страница 164: ...Maintenance Every 1000h 4812165801 pdf 2024 04 22 152...
Страница 179: ......
Страница 180: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...