Chapter 8 Diagnosis Function
73
code is relative coordinate or absolute coordinate. Under the general circumstance, the
arc’s IJ coordinate is relative coordinate, only minority several G code of arc’s IJ
coordinate is absolute coordinate.
8.7.6.4 Switch between Metric and Inches
As the figure 8.12 shows, default unit can be switched to either the metric or the
inches, after switching, the data’s units about length are all switched.
8.7.6.5 Short Line Fitting
As the figure 8.12 shows, when short line segments in the G code are too many and
continuous shake or shock occurs in the process of machine tool runs, set this parameter ”
Yes ”, in the general condition this parameter is set “No”.
8.7.6.6 Steel Plate Angle Memory
In the default condition, the angle after steel plate is adjusted has no memory. After
this parameter is set “Yes”, steel plate angle memory will be automatically stored, until the
steel plate is adjust again or the angle is cleared. As the figure 8.12 shows
,
when short line
segments in the G code are too many and continuous shake or shock occurs in the process
of machine tool runs, set this parameter “ Yes” , in the general condition this parameter is
set “No”.
8.7.6.7 F Instruction Forbidden
When this parameter is “Yes”, F instruction after G code which is used for limited
rate is ignored.
8.7.6.8 Manual Angle Input to Adjust Steel Plate
When this parameter is “Yes”, the manual input angle in the section of 4.3.3 is also
steel plate adjusting angle. This angle will be shown in the main interface, if open the
function of steel plate angle memory, this angle is also add to the steel plate adjust angle
and accordingly saved.
8.7.7 Language Switch
In the main interface, press
【
F5 Diagnose
】
,then press
【
F8 System definition
】
,then
press
【
F6 Language
】
, it will select needed language interface.
Содержание F2100B/T
Страница 146: ...Contact Information 137...