Chapter 3 Cutting Function
21
back to reference and stop has no limit.
3.7 Oxygen Gas Preheat Time Regulation
In the preheat process, press the START (F9) key to skip the process of preheat
and perforation delay, and immediately open the perforation signal then begin to
cut.
In the preheat process, press the STOP (F10) key to stop preheat, waiting for the
F9 key is pressed again.
In the preheat process, press the
【
F6
】
key then the preheat time will be reduced
to the current preheat time spent, and skip the process of preheat and perforation
delay, and open the perforation signal then begin to cut.
For example: the original system sets the preheat time of 60 seconds, when
preheat needed, the interface will count down, under normal circumstances, till 0, the
system begins the next step of cutting, but if the system has the remaining 10 seconds
of countdown time, press
【
F6
】
, then the system immediately stops preheat to begin
the next step of cutting, and records the preheat time of 50 seconds, the system
automatically thinks that users need preheat time of 50 seconds, the next preheat after
the null cutting when the preheat time becomes 50 seconds.
In the preheat process, each press the F7 key, preheat time increases by 15
seconds and the preheat time maintains the increased value till incision ending of
this time.
For example: The original system sets the preheat time of 60 seconds after the
null cutting, during the system countdown, each press
【
F7
】
, on the interface the
countdown increases by 15 seconds, and the next time you need to preheat, the initial
preheat time be 75 seconds.
3.8 Perforation Point Selection
Before you start cutting or cutting is paused, the function key prompt F8 is
"select new pierce", then press F8, the system will prompt: