Appendix 3 Interpretation of Wiring Connection between F2000 Series and Common THC
125
A3.2 Connection with HYD THC
Arcing feedback
04
13
24VG
F2000 input ports
4
1
2
3
8
6
7
IHSARCON
EXAUTO
UP
DOWN
GND5
ARCTRANS1
ARCTRANS2
F2000 output ports
HYD THC (to CNC)
24VG
16
18
02
15
Plasma arc starting
Lock THC
Torch up
Torch down
13
Plasma parameter
Range of value
Recommended value
Delay Before Arc
0
0
Pierce time
0
0
Torch up time
0-3
3
Arcing Check Time:
5-30
30
Position check Time:
0
0
Speed to lock THC
90-100
95
Distance to lock THC
0-15
10
Lose arc delay
0-1
0.5
Watch arc enable
Yes
Yes
The method of setting parameter:
F2100T, F2200T, F2300T (A/B), F2500T (A/B), F2600T:
F4 (Setups), F3 (Plasma).
Input definition
Port
Type
Position detect
05
●