Chapter 7 Parameter Setting
57
F1 Common
F4 Powder
F2 Flame
F8 Save
Marker Ignition Time 0.00 s
Marker Preheat Time 0.00 s
Mix powder Open Time 0.00 s
Mix powder Close Time 0.00 s
Marker Up Time 0.00 s
Marker Down Time 0.00 s
Marker Horizontal Offset 0.000 mm
Marker Vertical Offset 0.000 mm
F3 Plasma
F5 System
F7 Export
F6 Import
Fig 7.5 powder parameters
Marker Ignition Time
:
Input ≥0 arbitrary value, unit: s.
Marker Preheat Time
:
Input ≥0 arbitrary value, unit: s.
Mix powder Open/Close Time
:
Delay time of scatter powder mouth relative to spurt
powder mouth open/close, input ≥0 arbitrary value, unit: s.
Marker Up Time
:
The time of powder torch going up. Unit: s.
Marker Down Time
:
The time of powder torch going down. Unit: s.
Marker Horizontal Offset
:
Horizontal offset of powder gun relative to cutting torch.
Unit: mm.
Marker Vertical Offset
:
Vertical offset of powder gun relative to cutting torch. Unit:
mm.
7.5 System Parameters
The system parameters, as shown in Fig 7.6, are related with the precision of driver
shaft of the cutting machine, coordinate axis, increase/decrease of rate and little arc
processing limited parameter.