Chapter 7 Parameter Setting
61
F1 Common
F2 Flame
F3 Plasma
F5 System
F6 Import F7 Export
F8 Save
Horizontal Axis Pulse
125.000
n/mm
Vertical Axis Pulse
125.000
n/mm
Max cutting speed
2000.000
mmpm
Max G00 speed
6000.000
mmpm
Max Manual speed
3000.000
mmpm
Small arc limit
500.000
mmpm
Limit speed below radius
0.00
mm
Flame adjust time
0.40
s
Plasma adjust time
0.30
s
Emergency stop time
0.08
s
Start speed
250.000
mm
Max +X
100000.000
mm
Max +Y
100000.000
mm
Min -X
-100000.000
mm
Min -Y
-100000.000
mm
F4 Powder
Sure to export Parameter?
Fig.7.8 Parameter export
7.8 Save Parameters
After parameter modification, press
【
F8
】
to save, shown in Figure 7.9.
F1 Common
F2 Flame
F3 Plasma
F5 System
F6 Import F7 Export
F8 Save
F4 Powder
Parameter saved successfully
Fig.7.9 System Parameters
Note
:
when any parameter has been modified
,
you must take preservation operation
to keep modification valid, or the system will take the original parameters.
Содержание F2100B/T
Страница 146: ...Contact Information 137...