Chapter 7 Parameter Setting
55
Torch Up Time: When arc press is turned off, the time for the torch to lift up. Enter
any positive number, unit is s.
Arcing Check Time: Enter any positive number, unit is s. If not detected any
feedback signal of success arc starting within the detection time, the system prompts
an error message and terminates the current work of cutting, according memory
breakpoints to withdraw from the program. If detected feedback signal of success arc
starting within the detection time, the system stops detecting and cutting.
Position check Time: Enter any positive number, unit is s. Delay time of the success
of position check. If not detected any signal of success of position check within the
detection time, the system thinks that the position check is unsuccessful and sends out
an alarm. Otherwise, the system finishes the position check and starts position up.
Position up Time: Enter any positive number, unit is s. Before positioning check, the
time for the torch to lift up.
Close arc: In setting the rate of X%, open the output port, close the arc press signal,
to prevent the steel melting under low-speed cutting tip due to temperature is too high.
Distance to close arc: in the minimum distance of the cutting line of the initial
segment or end segment, close the arc voltage increases.
Lose arc delay: detect the delay time of the feedback of the broken arc, if there’s
still no arc voltage input, the situation is considered to be broken arc. This parameter
can effectively avoid the arc broken alert because of the sensitivity of the broken arc
detection in the cutting methods with lead, this guarantees the continuousness of the
cutting and avoid the interrupt of frequent alert.
Time to Lock THC before M08: broken arc check delay is independent of auto
turning high, it’s normally default value. Unit: s.
Watch arc enable: whether real-time detection of arc voltage signal in cutting
process or not.
If setting "yes", in the cutting process, the system detects he real-time arc voltage
feedback signal. If do not detect the signal, the system will stop the current work-piece
cutting and transmit alarm signal.
If installing a "No", then in the cutting process does not detect arc voltage feedback
signal.