Famed SU-02 Скачать руководство пользователя страница 13

Operating Manual for Operating Table SU-02.0

_____________________________________________________________________________________________________

-

release the central blockade of wheels (item 3.10 

Table mobility

-

with an assistance of a few people, carefully and slowly remove the table from the pallet,  then 
block the wheels  

-

add the headrest 

(item 3.11 Installation and operation of the headrest)

-

place the product in its destination which meets the requirements described in this manual (

item 

1.2 General requirements

),

-

on the basis of information given in item 

3  Operation

 check whether the table works as described 

in item 

5 Criteria on whose basis it is assessed whether product operation is correct or not

.

-

Caution!

If  the  product  is  not   fully   functional,   i.e.   the  output   parameters   differ  from  the 
description contained in this manual, the bed must not be used. This situation 
should   be   reported   to   the   producer   or   supplier.   The   use   of   an   improperly 
functioning product  may  result  in damages,  which will  encumber the  user and 
which will not be a matter of producer’s responsibility

3 Operation and use

3.1 Raising and levelling of table top

Height of table top is changed within the scope defined in technical data by pressing of the lever 
(drawing 1-3, item 10) of the hydraulic pump. Table top is lowered when the lever is raised. The foot 
pump installed in the table does not additional operation or maintenance. 

3.2 Longitudinal tilt of the table-top

to adjust longitudinal  tilt  of the table-top  (trendelenburg and anti-trendelenburg),  you should stand 
behind the backrest, put both hands on the handles (drawing 1-3 item 13 and 14), turn the right handle 
clockwise till you feel resistance (which releases the blockade of gas springs) and place table top in 
the required position (within the range of angles given in technical data). When you release the right 
handle, the table will be locked in the position.  Additionally after aggressive discharge of the right 
handle an automatic return of its rotation blockade should follow.  That is belonged to make sure for 
this fact through another test of handle turning (to the right) without blockade releasing, rotation of the 
handle should be impossible for execution.

Neurosurgical table top

Standard table top

Fig. 6

In neurosurgical table top the handle which is placed on the right side of the back rest segment should 
be put forward and turn to the headrest side.
It belongs to dismiss the handle after receiving of demanded side.

Caution!

When   performing   longitudinal  (Trendelenburg   or   reverse   Trendelenburg)   and   lateral  
tilting

,   patient   should   be   secured   against   uncontrolled   sliding   down   from   the 

operating table. Use shoulder supports, supporting rollers, side supports, belts 
and grips as securing elements.
Make   sure,   that   the   rotation   blockade   of   the   right   handle   of   longitudinal   tilt 
prevents its rotation!

 

_________________________________________________________________________________

page 13

Содержание SU-02

Страница 1: ...USER MANUAL Operating table SU 02 Factory no Version 12 00 ywiecka Fabryka Sprz tu Szpitalnego FAMED S A Appendixes 2 3 A List of Spare Parts...

Страница 2: ...edure was carried out in accordance with appendix VII of the directive Manufacturer ywiec Hospital Equipment Company FAMED S A Fabryczna 1 34 300 ywiec Phone numbers Infoline 48 33 866 63 75 24 hours...

Страница 3: ...er Every repair of the product must be done by a factory or an authorized service and recorded on the list of repairs which is supplied with the guarantee certificate Disregarding this requirement wil...

Страница 4: ...g the table avoid collisions Do not roll the table over electric cables If it is necessary to replace oil dangerous waste one should follow existing environmental protection regulations Notes concerni...

Страница 5: ...CHANGE OF ANGULAR POSITION OF THE FOOTRESTS 14 3 7 CHANGE OF ANGULAR POSITION OF DIVIDED FOOTRESTS 15 3 8 ROTATION OF THE FOOTREST 15 3 9 INSTALLATION AND REMOVAL OF THE FOOTREST 15 3 10 INSTALLATION...

Страница 6: ...exclusively in conformity with its destination and that it is used in appropriate conditions and in consistence with this manual The user is also obliged to take all necessary precautions in order to...

Страница 7: ...________________________________________________________________ 1 5Description of elements drawing 1 Operating table SU 02 standard version drawing 2 Operating table SU 02 Supermobile version _______...

Страница 8: ...angle change lever 17 Blockade of lever of back support angle adjustment 18 18 1 18 2 18 3 Kidney bench crank storage position adjustment position of kidney support adjustment position of lateral tilt...

Страница 9: ...m the floor 1000 mm 15 mm Backrest raise angle 70 Backrest lowering angle 40 Kidney bench raise angle 110 Footrest raise angle 4 and 5 sectional table top 15 Footrest raise angle 6 sectional table top...

Страница 10: ..._________________________________________________________________________ 1 7Use parameters The figure below indicates the most important functional parameters of the table drawing 4 _________________...

Страница 11: ...losely follow operating instruction for that equipment Improper operation may become a source of dangerous accidents There is a danger of serious burning of the patient through the contact with metal...

Страница 12: ...ng with the product manufacturer in order to ensure safe transport 2 2Unpacking and first use Caution If the product is installed by an authorised service of FAMED S A the user is released from the ob...

Страница 13: ...oes not additional operation or maintenance 3 2Longitudinal tilt of the table top to adjust longitudinal tilt of the table top trendelenburg and anti trendelenburg you should stand behind the backrest...

Страница 14: ...backrest segment Angle adjustment of the position of the back support segment Fig 1 3 position 2 is performed by muscle force with a gas spring back up In order to adjust the segment position push the...

Страница 15: ...be correctly meshed When the knob is being turned down one should check if the toothed bars are meshed 3 9Installation and removal of the footrest The footrest may be placed and removed from the seat...

Страница 16: ...he table The table in this version is equipped with central blockade of every wheel Pedal of central blockade has three positions upper direction blockade Fig 2 position 24 3 middle all wheels unblock...

Страница 17: ...ation of potential equalization in the operations room The cable is provided in standard table accessories 3 15 Collisions In some extreme positions of the table in particular when accessories install...

Страница 18: ...19 6 18 Specialist headrest WS 21 5 19 Laryngology ophthalmic headrest with track adjustment WS 21 7 20 Head rest for cervical kerb WS 21 8 21 Hand support WS 22 5 22 Body strap WS 23 0 23 gynaecologi...

Страница 19: ...e in any direction should not cause tilting or moving 2 Check mechanisms of adjustment of location of the segments controlled by gas springs by a change of position and the lock see item 3 Operation T...

Страница 20: ...roduct accessories should be reported immediately to a person in charge of such issues The bed which can not be safely operated e g damaged electric or mechanical elements must not be used till it is...

Страница 21: ...protections on pivot bolts Check whether the lock and table moving system work Check the hydraulic pump Check whether gas springs work correctly Table top check whether the trendelenburg mechanism wo...

Страница 22: ...ntification When sending asking any questions concerning the table and when ordering spare parts please give the serial number of the table placed on the nameplate and the guarantee certificate The se...

Страница 23: ...rating Table SU 02 0 _____________________________________________________________________________________________________ 7 2 Labels __________________________________________________________________...

Страница 24: ...ing and disinfection you should not use agents containing active oxygen and chlorine 5 Maximum authorized workload 150 kg 6 Attention read user manual 7 Longitudinal tilt Trendelenburg anti Trendelenb...

Страница 25: ...____________ 13 Table top height adjustment 14 Table s brake 15 Central wheel lock Notice The producer reserves the right to introduce in the product modifications resulting from technical progress wh...

Страница 26: ...C047310000000000 3 14 Potential balance cable 1 S1115000004258 2 15 Pin of potential balance 1 S11155000004256 2 16 Sliding sleeve 4 S30250100000200 2 17 Guiding sleeve 4 C073600000014000 2 18 Trende...

Страница 27: ...k rest rail I 2 C047311000020000 2 47 Crank set 1 C067204000000000 2 48 Protection 1 C067200000005000 3 49 Arm 1 C080300000700000 2 50 Screw 1 C080300000011000 2 51 Hand II 1 C047311000011000 2 52 Pro...

Страница 28: ...list Symbol SU 02 Edition 06 04 2007 Package should contain Operating table SU 02 set without headrest 1 pce and Headrest 1 pce SG 10 0 Potential equalization cord 1 pce index S11155000015625 Additio...

Отзывы: