Fagor
M
odular Drives and Motors
Q
uick
R
eference. Ref.2104
MQR-41/84
ASSEMBLING PRECISION
Associate the accuracies of the elements with the code assigned
according to the table in order to interpret later data
.
FM7. E01|E02 series. Foot mounting - flange mounting
FM7. E01|E02 series. Foot & flange mounting
FM7. E03 series. Flange mounting
FM7. HS3 series. Flange mounting
HOLDING BRAKE
FM7 motors do not offer the holding brake in any of their models
.
FAN
All FM7 series spindle AC motors have an electrical cooling fan that
generates a constant air flow regardless of the motor turning
direction. This assures proper motor cooling in all duty cycles. This
fan starts turning when connected to the three-phase line.
Units in mm
L
LA
LB
LC
LG
LH
LL
LR
LD
LE
LF
Z
D
I
KD
KL
KI
KE
FM7-D075-S1D0-HS3
715
215
180h7
204
20
250
446
60
401
256
190
15
204
271
42.5
158
250
114
FM7-D110-S1D0-HS3
751
265
230h7
250
25
300
476
70
420
271
205
15
260
343
42.5
183
279
131
Units in inches
L
LA
LB
LC
LG
LH
LL
LR
LD
LE
LF
Z
D
I
KD
KL
KI
KE
FM7-D075-S1D0-HS3
28.1
8.4
7.1h7
8.0
0.7
9.8
17.5
2.3
15.7
10.0
7.4
0.5
8.0
10.6
1.6
6.2
9.8
4.4
FM7-D110-S1D0-HS3
29.5
10.4
9.1h7
9.8
0.9
11.8
18.7
2.7
16.5
10.6
8.0
0.5
10.2
13.5
1.6
7.2
10.9
5.1
Units in mm
L1
L2
L3
I1
I2
Q
mxl
S
X1
X2
X3
X4
dx
FM7-D075-S1D0-HS3
137
210
308
288
33
60
M12 x1.25
28h6
31
14.5
13
1.0
16
FM7-D110-S1D0-HS3
142
208
331
320
30
70
M16 x1.50
38h6
38
17.0
15
1.0-1.5
20
Units in inches
L1
L2
L3
I1
I2
Q
mxl
S
X1
X2
X3
X4
dx
FM7-D075-S1D0-HS3
5.39
8.26
12.12
11.33
1.30
2.36
M12 x0.04
1.10h6
1.22
0.57
0.51
0.03
0.63
FM7-D110-S1D0-HS3
5.59
8.18
13.03
12.59
1.18
2.75
M16 x0.05
1.49h6
1.49
0.66
0.59
0.03-0.05
0.78
Code Measurement
A
Parallelism of shaft extensión
B
Rotational excentricity of shaft extension (runout)
C
Shaft runout at the end
D
Concentricity between flange and shaft diameters
E
Concentricity of the support side of the flange with respect to
the machine axis
F
Perpendicularity of the support side of the flange with respect
to the foot
Units in mm
A
B
C
D
E
FM7-A037-
3
-E0
0.03
0.02
0.020
0.040
0.040
FM7-A055-
3
-E0
0.03
0.02
0.020
0.040
0.040
FM7-A075-
3
-E0
0.033
0.022
0.022
0.040
0.040
FM7-A090-
3
-E0
0.033
0.022
0.022
0.040
0.040
FM7-A110-
3
-E01
0.033
0.022
0.022
0.046
0.040
FM7-A150-
3
-E0
0.033
0.022
0.022
0.046
0.040
Units in mm
A
C
D
E
F
FM7-A110-
5
-E01
0.033
0.022
0.046
0.04
0.130
FM7-A150-
5
-E0
0.033
0.022
0.046
0.04
0.130
Units in mm
C
D
E
FM7-D055-S1D0-E03
0.020
0.040
0.04
FM7-D075-S1D0-E03
0.022
0.040
0.04
FM7-D110-S1D0-E03
0.022
0.046
0.04
Units in mm
C
D
E
FM7-D075-S1D0-HS3
0.022
0.040
0.04
FM7-D110-S1D0-HS3
0.022
0.046
0.04
MANDATORY.
Make sure that the fan is turning in the
direction indicated on the label that is located on the
outside of the body and that the air flowing as shown in
the drawing below.
(a) Flange mounting
(b) Foot mounting
The fan will blow the hot air towards the rear of the motor in both types
of connections. However, it will be necessary to verify that the turning
direction is the one shown on the label.
(a)
Flange mounting
(b)
Foot mounting
If connected Z1-L1, Z2-L2 and Z3-L3 the fan will turn in the opposite
direction to the one indicated on the label. Observe that the phases are not
swapped.
AI
R
FL
O
W
F
AN
M
O
T
O
R
RO
TA
T
IO
N
C on n ect i on f or t h e d i r ect i on sh ow n on f a n l a bel
Z 1
Z 2
Z 3
L 2
L 1
L 3
Note that phases L1 and L2 are swapped for proper air flow and motor
turning directions indicated on the outside label.
The fan connection to the three/phase line is done through 4/wire cable
with a minimum section of 1.5 mm² per wire.
L1
Fan connection terminal box
To three-phase line
L3
L2
Содержание 2104
Страница 1: ...FAGOR AUTOMATION Ref 2104 Original instructions FAGOR AUTOMATION DDS Modular Quick Reference...
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 82: ...MQR 82 84 Fagor Modular Drives and Motors Quick Reference Ref 2104 User notes...
Страница 83: ...Fagor Modular Drives and Motors Quick Reference Ref 2104 MQR 83 84 User notes...