RESISTOR MODULE, ER-TH-X/X & ER+TH-18/X+FAN
External resistors are used to dissipate the excess of energy
generated at the power bus in a braking process of electrical motors
and cannot be dissipated by the internal resistor of the module
(power supply). These resistors do not require external electrical
supply.
CAPACITOR MODULE, CM-1.75
This module stores the energy returned while the motors are braking.
The capacitor module should also be used when having systems that
sporadically request high current peaks from the power bus hence
increasing the bus' own capacity.
From the energy point of view, installing a capacitor module is more
efficient than installing external braking resistors.
BUS PROTECTION MODULE, BPM
Install in DDS systems having:
Synchronous spindle and only when required by the application.
Purpose. Protect the power semi-conductors (IGBTs) of the drive that
governs it, thus preventing damage to the unit due to a very high
voltage that may be generated at the power bus because the braking
energy cannot be returned when a voltage drop occurs and/or,
RPS pow. supply when only the controlled stop is to be ensured.
Purpose. To ensure a controlled stop of the motor due to mains failure
because the energy may be dissipated while braking at the external
Ballast resistors installed in the BPM module. Not installing this
module will result in an uncontrolled stop (by inertia) in case of a
voltage failure due to an over-voltage error of the bus because there
are no resistors to dissipate the braking energy.
MAINS FILTER
Absolutely necessary for complying with the European Directive on
Electromagnetic Compatibility 2014/30/EU or the International
Standard IEC 1800-3. The filter
·
MAIN FILTER 42A-A
·
is designed
for PS-25B4, XPS-25 and RPS-20,
·
MAIN FILTER 130A-A
·
is
designed for PS-37-L, PS-65A, XPS-65 and RPS-75,
·
MAIN FILTER
75A
·
is designed for RPS-45 and
·
MAIN FILTER 180A
·
is designed
for RPS-80.
XPS CHOKES & RPS CHOKES
The CHOKES (inductance) must only be installed with regenerative
power supplies (XPS and RPS).
XPS power supplies have their own associated XPS choke. RPS
power suppli-es have their own associa-ted RPS choke.
When returning power to mains, the impedance of mains for the
outgoing currents is very low. Thus, the up ramps of this current must
be limited with a CHOKE
.
SELECTING THE EXTERNAL BALLAST RESISTOR
Non-regenerative power supplies PS-37-L, PS-25B4 and PS-65A
have three micro-switches for selecting the external Ballast resistor.
It is also possible to disable the
«I²t»
protection when selecting the
internal resistor or having the RM-15 module (discontinued)
because they both include a protection with their own thermostat
protection.
CAPACITOR MODULE
·
A
·
APS-24
·
B
·
BPM
·
C
·
CM-1.75
·
D
·
ER+TH-X/X EXT. THERMOSTAT
·
E
·
ER+TH-X/X INT. THERMOSTAT
·
F
·
ER+TH-18/X+FAN
·
G
·
MAIN FILTER XA
·
H
·
MAIN FILTER XA-A
·
A
·
·
B
·
·
C
·
·
D
·
·
H
·
·
E
·
·
G
·
·
F
·
Note.
This system has been manufactured in accordance with the
EN 60204-1 Standard in compliance with European Directive
2014/35/EU on Low Voltage.
·
A
·
·
A
·
CHOKE XPS-25
·
B
·
CHOKE XPS-65-A
·
C
·
CHOKE RPS-20 | CHOKE RPS-45 | CHOKE RPS-75-3
·
B
·
·
C
·
PO
W
ER
S
UP
PL
Y
S3
S2
S1 RESISTOR
OFF OFF OFF INTERNAL
OFF OFF ON ER+TH-18/1100
OFF ON OFF ER+TH-18/1000+FAN
OFF ON ON ER+TH-18/1800
ON OFF OFF ER+TH-18/2200
ON
ON OFF RM-15 · discontinued ·
ON OFF ON ER+TH-18/1500+FAN or
ER+TH-18/2000+FAN
Note. If you wish to install a
NON-FAGOR resistor, please
read below.
ON
ON ON ER+TH-18/1500+FAN or
ER+TH-18/2000+FAN
Note. If you wish to install a
NON-FAGOR resistor, please
read below.
REPRESENTS THE MOVING ELEMENT.
·
A
·
PS-37-L | PS-65A
·
B
·
PS-25B4
ON
S1
S2
S3
TOP VIEW
·
A
·
On PS-25B4 power supplies, install
the indicated resistor.
On PS-37-L and PS- 65A power
supplies, install in parallel 2x the
indicated resistor.
·
A
·
·
B
·
Note.
When installing a NON-FAGOR resistor, only use this switch setting when the power of your resistor
is greater than any of the ones shown in this cell of the tables provided by FAGOR. Ignoring this warning
MAY CAUSE THE DESTRUCTION of the resistor WITHOUT PRIOR WARNING. Therefore, make sure to
install your own protection system when installing a NON-FAGOR resistor of lower power.
Содержание 2104
Страница 1: ...FAGOR AUTOMATION Ref 2104 Original instructions FAGOR AUTOMATION DDS Modular Quick Reference...
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 82: ...MQR 82 84 Fagor Modular Drives and Motors Quick Reference Ref 2104 User notes...
Страница 83: ...Fagor Modular Drives and Motors Quick Reference Ref 2104 MQR 83 84 User notes...