POWER SUPPLY MODULES. PS
Technical data
POWER SUPPLY MODULES. XPS
Technical data
PS-37-L
Line voltage
3-ph, Vac
from
200
(1-10 %) to
240
(1+10 %)
Line frequency
48 ... 62 Hz
Mains power consumption
95 A
Min. connection cable section
50 mm²
Power bus voltage
VBUS
nom
280 Vdc / 340 Vdc
Rated (peak) output current
120 A (360 A, 1 s)
Rated (peak) output power
37 kW (110 kW, 1 s)
Power for the module control circuit
24 Vdc (between 21-28 Vdc)
Consumption of the module control
circuit itself
1 A at 24 V (24 W)
Internal Ballast resist. (power)
9
(600 W)
Energy pulse to be dissipated
36 kWs (2.8 s)
Ballast circuit
ON/OFF
445 Vdc / 440 Vdc
Min. external Ballast resistance
9
Filter capacity
940 µF, 450 Vdc
Max.
SYSTEM OK
contact voltage
125 Vac, 150 Vdc
Max.
SYSTEM OK
contact current
2 A
Module width
117 mm / 4.61 in
Module weight
9.9 kg / 22 lb
Power dissipated at max. load
275 W
Ambient temperature
1
0°C/45°C (32°F/113°F)
Storage temperature
-25°C/60°C (-13°F/140°F)
Max. humidity
< 90 % non condens. at 45°C/113°F
Max. installation altitude
2000 m (6561 ft) above sea level
Operating/Shipping vibration
1 g / 1.5 g
Sealing
IP 2x
Protections
Overvoltage, heat-sink temperature,
hardware error, Ballast overload.
PS-65A
Line voltage
3-ph, Vac
from
400
(1-10 %) to
460
(1+10 %)
Line frequency
48 ... 62 Hz
Mains power consumption
100 A
Min. connection cable section
50 mm²
Power bus voltage
VBUS
nom
565 Vdc / 650 Vdc
Rated (peak) output current
*
120 A (360 A, 1 s)
Rated (peak) output power
65 kW (195 kW, 1 s)
Power for the module control circuit
24 Vdc (between 21-28 Vdc)
Consumption of the module control
circuit itself
1 A at 24 V (24 W)
Internal Ballast resistance (power)
*
9
(600 W)
Energy pulse to be dissipated
36 kWs (0.6 s)
Ballast circuit
ON/OFF
768 Vdc / 760 Vdc
(712 Vdc / 704 Vdc)
Min. external Ballast resistance
9
Filter capacity
940 µF, 900 Vdc
Max.
SYSTEM OK
contact voltage
125 Vac, 150 Vdc
Max.
SYSTEM OK
contact current
2 A
Module width
117 mm / 4.61 in
Module weight
9.9 kg / 22 lb
Power dissipated at max. load
275 W
Ambient temperature
*
0°C/45°C (32°F/113°F)
Storage temperature
-25°C/60°C (-13°F/140°F)
Maximum humidity
< 90% non condens. at 45°C/113°F
Max. installation altitude
2000 m (6561 ft) above sea level
Operating/shipping vibration
1 g / 1.5 g
Sealing
IP 2x
Protections
Overvoltage, heat-sink temperature,
hardware error, Ballast overload.
*
See derating curves in case of high temperatures.
PS-25B4
Line voltage
3-ph, Vac
from
400
(1-10 %) to
460
(1+10 %)
Line frequency
48 ... 62 Hz
Mains power consumption
38 Arms
Max. connection cable section
10 mm²
Power bus voltage
VBUS
nom
565 Vdc / 650 Vdc
Rated (peak) output current
*
45 A (135 A, 1 s)
Rated (peak) output power
25 kW (75 kW, 1 s)
Internal Ballast resistance (power)
*
16.5
(500 W)
Energy pulse to be dissipated
6 kWs (0.2 s)
Ballast circuit
ON/OFF
768 Vdc / 760 Vdc
(712 Vdc / 704 Vdc)
Min. external Ballast resistance
16.5
Filter capacity
820 µF, 900 Vdc
Max.
SYSTEM OK
contact voltage
125 Vac, 150 Vdc
Max.
SYSTEM OK
contact current
2 A
Module width
77 mm/3.03 in
Module weight
6.0 kg/13.2 lb
Power dissipated at max. load
180 W
Output voltage, max. current
24 Vdc (5 %), 10 A
Auxiliary power supply connection
Line voltage
3-ph, Vac
from
400
(1-10 %) to
460
(1+10 %)
Line frequency
48 ... 62 Hz
Mains consumption
0.72 A (400 Vac); 0.63 A (460 Vac)
Max. Inrush current
23.9 A (460 Vac)
Bus consumption
0.485 A (565 Vdc); 0.44 A (650 Vdc)
Bus max. voltage
790 Vdc
Ambient conditions and other characteristics
Ambient temperature
*
0°C/45°C (32°F/113°F)
Storage temperature
-25°C/+60°C (-13°F/+140°F)
Maximum humidity
< 90% non condens. at 45°C/113°F
Max. installation altitude
2 000 m (6561 ft) above sea level
Operating/shipping vibration
1 g / 1.5 g
Sealing
IP 2x
Protections
Overvoltage, heat-sink temperature,
hardware error, Ballast overload
*
See derating curves in case of high temperatures.
XPS-25
XPS-65
Line voltage
3-ph, Vac
from
400
(1-10 %) to
460
(1+10 %)
Line frequency
48 ... 62 Hz
Mains power consumption
38 A
100 A
Min. connection cable section
16 mm²
50 mm²
Power Bus voltage VBUSnom
565 Vdc / 650 Vdc
Rated (peak) output current
·
1
·
45 A (100 A, 1s)
120 A (120 A, 1s)
Rated (peak) output power
25 kW (55 kW, 1s) 65 kW (108 kW, 1s)
Regenerating circuit
ON/OFF
voltage
Vline x 1.414 + 30 V
Rated regenerated current
(returned to mains)
·
1
·
25 A
62 A
Rated regenerated power
(returned to mains)
1
20 kW
50 kW
Choke-drive cable
- max length: 2 m (80 in) -
16 mm²
50 mm²
Output voltage of the auxiliary
power supply
24 Vdc ± 5 %
Max. current supplied
8 A at 24 V (192 W)
Mains consumption for
24 Vdc generation
0.72 A (400 Vac), 0.63 A (460 Vac)
Содержание 2104
Страница 1: ...FAGOR AUTOMATION Ref 2104 Original instructions FAGOR AUTOMATION DDS Modular Quick Reference...
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 82: ...MQR 82 84 Fagor Modular Drives and Motors Quick Reference Ref 2104 User notes...
Страница 83: ...Fagor Modular Drives and Motors Quick Reference Ref 2104 MQR 83 84 User notes...