Fagor
M
odular Drives and Motors
Q
uick
R
eference. Ref.2104
MQR-47/84
Electrical characteristics
PRECAUTIONS WHEN INSTALLING THE MOTOR
This section describes the environmental precautions to bear in mind
when installing the motor.
The motor must be installed under the following conditions:
Leave enough clearance for the cooling fan to blow the air out.
The minimum clearance between the machine and the exit of the
motor fan is 100 mm (3.94 in).
Install the motor in a clean place, away from oil and water. If there
is a chance that the motor may be exposed to oil or water, cover
it for protection. If dirty oil or water gets into the motor, it would
decrease the isolation resistance and cause a grounding failure.
Make sure that the motor is firmly secured to the floor or with the
flange because the weight of the motor the dynamic load when it
is running may generate vibrations.
Install the motor in an environment free of dust and metal
particles. The motor has an integrated fan with an internal
structure that provides cooling air to the motor. Blocking the air
flow with dust other strange elements may decrease the efficiency
of the cooling system.
CONSIDERATIONS FOR MOTOR INSTALLATION
CAUTION !
Note that when installing transmission pulleys or
gearboxes, any blow to the shaft reduces its useful life, of
bearings, and may damage the encoder.
Therefore, do not hit it for any reason.
BALL BEARINGS. USEFUL LIFE
The useful life of the bearings is aproximately 5000 hours of
continuous operation at max. speed. The references of the bearings
located at the shaft end and at the fan end are indicated on the
identifications plate stuck on one side of the motor.
MOUNTING ARRANGEMENTS
·
IM CODE
·
IDENTIFICATION
Names
The denomination of each motor is made up of letters and digits
that mean the following.The sales model is stored in the motor
encoder. The drive software can automatically adjust the motor
parameters by reading that “sales model” from the encoder
memory.
Motor model nomenclature
Motor
Voltage Frequency Power Current
Vac
Hz
W
A
FM9-B037-C5C
-E01
220
220
50
60
195
250
0.92
1.15
FM9-B
-C5C
-E01
400
460
50
60
1500
1750
3.25
3.20
FM9-A
-C5C
-E01
400
460
50
60
1500
1750
3.25
3.20
MANDATORY.
The flange and the shaft of the motor have
an anticorrosive layer of paint or grease. The flange, the
shaft and the key must be cleaned before installing the
motor.
Fan connection
FM9-B055-C5C
-E01-A, FM9-B071-C5C
-E01,
FM9-A100-C5C
-E01, FM9-B113-C5C
-E01,
FM9-A130-C5C
-E01
Note. Observe that the fan
connecting terminals are in
another smaller terminal box
attached to the fan.
The fan connection to the 3-phase
line is done through 4/wire cable
with a min. section of 1.5 mm² per
wire.
FAN
CONNECTION
TERMINAL BOX
IM B35
IM V36
IM V15
IM B3
EN 60034-7, code I
IM B5
IM V6
IM V5
IM V1
IM V3
$
VLQJOHZLQGLQJ
UHYPLQ
)0&&
)$*250$6<1&+52128602725
%$6(63(('
)(('%$&.
&
9SSVLQXVRLGDOHQFRGHUSSW
%
UHYPLQ
1RWH7KHN:IRUHDFKPRGHODUHWKHRQHVJLYHQE\WKLV
0272532:(5N:
'XW\6
YDOXH(J$Q)0%PRWRUFDQSURYLGHXSWRN:
LQ6GXW\
$
%
(
02817,1*
)ODQJH)RRW
'(*5((2)
&
9
9,%5$7,21
6+$)7
.H\OHVV
:LWKNH\
KDOINH\EDODQFLQJ
5(/($6(
9PD[XSWRUHYPLQ
&D[LVHQFRGHU
63(&,$/
1RQH
6SHFLDOFRQILJXUDWLRQ
$=
1RWH6SHFLDOFRQILJXUDWLRQ0RWRUPRGHO)0%&&[($6PDOOHUVKDIWH[WHQVLRQGLDPHWHUPP
Содержание 2104