PVS 407D • SIS Communication and Control
19
SIS Communication
and Control
The switcher can be configured and controlled with Extron Simple Instruction Set (SIS)
commands when connected to a host computer or other device (such as a control system).
Attach the host device to the rear panel RS-232 connector, the LAN port, or the front
panel USB port. Commands can be entered using a Telnet application such as the Extron
DataViewer, available at
(see the
DataViewer Help
file for more details).
This section describes SIS communication and control. Topics in this section include:
•
Host and Switcher Communication
•
•
•
The switcher uses a protocol of 9600 baud, 1 stop bit, no parity, and no flow control (see
Host and Switcher Communication
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the switcher determines that a
command is valid, it executes the command and sends a response to the host device. All
responses from the switcher to the host end with a carriage return and a line feed
(CR/LF =
]
), indicating the end of the response character string (one or more characters).
Switcher-Initiated Messages
When a local event such as a front panel selection or adjustment takes place, the PVS 407D
responds by sending a message to the host. No response is required from the host.
Example switcher-initiated messages are listed here.
•
]
©
Copyright
2019,
Extron
Electronics,
PVS
407D,
Vx.xx,
60-1466-01
]
(where Vx.xx is the firmware version number and
60-1466-01
is the
product number ).
•
Chn
X!
]
(where
X!
is the input number when an input switches).
Copyright Information
The copyright message is displayed upon connecting to a switcher via TCP/IP or Telnet or
via RS-232 after a power cycle.
]
© Copyright
YYYY
, Extron Electronics, PVS 4
0
7D, V
x.xx
,
6
0
-1466-
0
1
]
Ddd
,
DD MMM YYYY HH
:
MM
:
SS
]
(day, date, and time as in
Fri,
2
0
Nov 2
0
15 11:27:33
).
Password Information
The
]
Password:
prompt requires a password (administrator level or user level) followed
by a carriage return. The prompt is repeated if the correct password is not entered. If the
correct password is entered, the unit responds with
]
Login Administrator
]
or
]
Login User
]
, depending on password entered. If passwords are the same for both
administrator and user, the unit defaults to administrator privileges.