35
PVS 407D • SIS Communication and Control
Command
ASCII Command
(host to switcher)
Response
(switcher to host)
Additional Description
Reboot system
E
1BOOT
}
Boot1
]
Restarts the system after a firmware
upgrade (required).
Reboot network
E
2BOOT
}
Boot2
]
Restarts network (see Note below).
NOTE:
Changes made to any TCP/IP settings do not take effect until the reboot network command,
E
2BOOT
is issued.
Set IP, Subnet, and Gateway (all at once)
NOTE:
Setting any values with the CISG command changes DHCP from on to off (default). Settings take place immediately without the need for
E
2BOOT
.
Set IP
E
1*
X10(
CISG
}
Cisg
•
1*
X10(
/
X11#
*
X11!]
1= NIC number.
Set IP/subnet
or
E
1*
X10(
*
X11)
CISG
}
Cisg
•
1*
X10(
/
X11#
*
X11!]
Set IP/subnet
E
1*
X10(
/
X11#
CISG
}
Cisg
•
1*
X10(
/
X11#
*
X11!]
Set IP/subnet/Gateway
or
E
1*
X10(
*
X11)
*
X11!
CISG
}
Cisg
•
1*
X10(
/
X11#
*
X11!]
Set IP/subnet/Gateway
E
1*
X10(
/
X11#
*
X11!
CISG
}
Cisg
•
1*
X10(
/
X11#
*
X11!]
View IP/subnet/Gateway (all)
E
1
CISG
}
X10(
/
X11#
*
X11!]
KEY:
X10(
= IP address
xxx.xxx.xxx.xxx
(
192.168.254.254
= default)
X11)
= Subnet address
xxx.xxx.xxx.xxx
(
255.255.0.0
= default)
X11!
= Gateway address
xxx.xxx.xxx.xxx
(
0.0.0.0
= default)
X11#
= Prefix (subnet mask bits)
Subnet 255.255.0.0 is represented as a prefix value by /16.
Read MAC address
E
CH
}
Verbose mode 2/3
X10$]
Iph
• X10$]
00-05-A6-
xx
-
xx
-
xx
View number of Ethernet
connections
E
CC
}
X4$]
View the number of open connections.
KEY:
X4$
= Number of open connections
X10$
= Hardware MAC address
(
00-05-A6
-xx-xx-xx
)