Power Save Modes
The PVS 407D is an ENERGY STAR
®
qualified device, and has five Power Save modes,
(see the table below for mode descriptions and
Mode
Type
Activation
Device and
System power
Wake-up trigger
Setup
Command
0
Normal
None
Fully powered. Status
LED is green.
N/A
Default state,
SIS command
reset
1
Auto
Power
Save
Timed after setup.
If no audio and
video signal (from
inputs 1 to 6) or
audio signal (from
switchable program
inputs, Aux input,
and VoiceLift input)
is detected for
25 consecutive
minutes, mode 2 is
enabled.
Amplifier and rest of
system is powered until
mode 2 is entered. The
Status LED is green in
mode 1.
An active switchable
program audio signal which
is referring to selectable
inputs 1 to 7, or when an
input is switched, or if the
volume is adjusted.
The audio timer is reset.
Can also be woken by SIS
command (resets device to
mode 0).
By SIS
command or
Configuration
Software
(PCS)
2
Forced
Auto
Power
Save
Instant
Amplifier is off. Rest of
system is powered. The
Status LED is amber.
If entered from mode 1,
can be woken by an active
switchable program audio
signal which is referring to
selectable inputs 1 to 7, or
when an input is switched,
or if the volume is adjusted.
Reverts to mode 1.
Either from
mode 1 or set
instantly by
SIS command
If set instantly by SIS
command, can only be
woken by SIS command,
input selection, or volume
adjustment.
Reverts to the previously set
mode (0 or 1).
3
Forced
Standby
Power
Save
Instant
Amplifier is off. Wallplates
off. VLR 102 receiver off.
Rest of system is powered.
Status LED is amber.
On PVS 407D, only USB,
RS-232, network switch
ports, and input buttons
are functional.
Pressing the front input
toggle button, or switching
the inputs from the attached
MLC controller.
Reverts to the previously set
mode (0 or 1).
Can also be woken by SIS
command.
SIS command
only
4
Forced
Network
Standby
Power
Save
Instant
Amplifier is off. Wallplates
off. VLR 102 receiver off.
Network switch off. Rest
of system is powered.
The Status LED is amber.
On PVS 407D, only
USB, RS-232, and input
buttons are functional.
Pressing the front input
toggle button, or switching
the inputs from the attached
MLC controller.
Reverts to the previously set
mode (0 or 1).
Can also be woken by SIS
command.
SIS command
only
NOTE:
Front USB and rear remote RS-232 ports are powered and active all the time regardless of the
current power save mode.
PVS 407D Switcher • Operation