PVS 407D • SIS Communication and Control
Command
ASCII Command
(host to switcher)
Response
(switcher to host)
Additional Description
Passwords
Set administrator password
E X10*
CA
}
Ipa
• X10*]
Set the administrator password to
X10*
.
Read administrator password
E
CA
}
X10*]
View whether the administrator
password exists (see Note below).
NOTES:
•
The factory configured passwords for all accounts on this device have been set to the device serial number. In the event of a complete system
reset, the passwords convert to the default, which is no password for this device. Passwords are case sensitive.
•
Reading password: RS-232 and IP connections responds with 4 asterisks (****) if password exists and empty if not, instead of the actual
password.
Reset (clear) administrator
password
E•
CA
}
Ipa
•]
Reset (clear) the administrator
password.
Set user password
E X10*
CU
}
Ipu
•X10*]
Set the user password to
X10*
.
Read user password
E X10*
CU
}
X10*]
View whether the user password exists
(see Note above).
Reset (clear) user password
E•
CU
}
Ipu
•]
Reset (clear) the user password.
KEY:
X10*
= Password
•
Need to be logged in as administrator to perform these tasks.
•
Maximum length is 12 characters.
•
All human-readable characters are permitted except “/”, “\”, “|”, “ “, and “*”.
•
Passwords are case-sensitive and cannot be a single space.
•
User password cannot be assigned if no admin password exists, (returns E14).
•
If admin password gets cleared, then user password is removed too.