4. Coat the tip of the new thermocouple with heat trans-
ferring paste (see chapter „5.3.1 Tools and operating
materials“) and insert it into the bore in the nozzle as far
as it will go.
Picture 60: Coated tip of thermocouple
Picture 61: Installation of the new thermocouple
5. Bend the thermocouple carefully and wind it along the
heater. At the same time slide the protective tube over
the pressure tube to fix the already positioned part of the
thermocouple.
6. Check functioning of the new thermocouple by heating
up the nozzle with a controller.
7. For notes for installation of the nozzle please refer to
chapter „5.5 Installation of L2X Drop-in hot runner sys-
tems“.