32
HPS-III-Heißkanalsystem_Vorspann_BA_V-2-0_EN
Installation
NOTE!
Only use approved standard parts
Damage to the HPS III hot runner system and/or components of the surrounding injection mould.
•
Only standard parts which are approved for operation in EWIKON hot runner systems must be used.
The following standard parts with the associated standards are approved for EWIKON hot runner systems. Particularly for
screws the associated strength classes (see chapter 5.5 Assembly of the system / the components) and tightening torques
(compare chapter „9. Tightening torques“) must be adhered to.
Standard part
Valid standard
Invalid/old standard
Hexagon socket head cap screw
DIN EN ISO 4762 (ISO 4762)
DIN 912
Hexagon socket head cap screw - low
head, with pilot recess
DIN 6912
-
Countersunk screw
DIN EN ISO 10642 (ISO 10642)
DIN 7991
Parallel pin
DIN EN ISO 2338 (ISO 2338)
DIN 7
Parallel pin with internal thread
DIN EN ISO 8735 (ISO 8735)
DIN 7979
Flat washer
DIN EN ISO 7089 (ISO 7089)
DIN 125-1 (DIN 125)
Flat washer
DIN EN ISO 7092 (ISO 7092)
DIN 453-1 und DIN 433-2
Feather key
DIN EN ISO 773 (ISO 773)
-
Lock ring
DIN 471
-
Split pin
DIN EN ISO 8752 (ISO 8752)
DIN 1481
Chart 10: Approved standard parts for EWIKON hot runner systems
5.3.2 Standard parts