38
HPS-III-L2X-Heißkanalsystem_Montage_BA_V-2-0_EN
Installation of L2X Drop-in hot runner systems
Picture 24: Check of reference dimensions
z347-02
Dimensions to be checked:
Dimension
H3 + ∆S
between the upper surface of the nozzle
retainer frame plate (pos. 53) and the contact surface for the
centre support of the manifold.
Dimension
H4 + ∆S
between the upper surface of the nozzle
retainer frame plate (pos. 53) and the contact surface of the
pressure pads underneath the manifold.
Compare both dimensions to the values given in the
drawing provided by EWIKON.
Preliminary measures
Introduction
The installation steps described in the following generally apply for L2X Drop-in hot runner systems for open gating as well
as for valve gate systems. Any differences are explicitly mentioned in the describing text.
Picture 25: Preliminary measures
z347-03
1. Lift the pre-installed system carefully out of the transport
crate. EWIKON recommends to use attachment swi-
vels M12 only (pos. a, min. quality category 8 = 500 kg
loading capacity for α = 0°, see chapter „5.3.1 Tools and
operating materials“). Distance bolts with appropriate
length (item number see EWIKON L2X catalogue) may
be used in exceptional cases only. Please pay attention
to the notes in chapter „5.1 Transport“.
2. Screw the enclosed centring aids (pos. 14) into the
nozzle retainer frame plate (pos. 53).
3. Connect the hot runner controller to the connector box.
Please pay attention to the notes in chapter
„5.6 Electrical connection of hot runner systems“.
4. Heat the manifold up to 120 °C.
Suspended load
Death and severe crushing of body or extremities.
•
Keep clear of and do not pass under suspended loads.
•
Keep clear of suspended loads while they are being transported.
•
Do not touch lifting devices and lifting accessories while lifting
the load.
•
Only lift, transport and set down loads, if you have received ap-
propriate training.
•
Only use suitable and undamaged lifting devices and lifting
accessories which are checked regularly.
•
Do not exceed the maximum load limit of lifting accessories.
Sharp edges and heavy components
•
Cut injuries to body and extremities, mainly to the hands.
•
Crushing of fingers or hand.
Hot surfaces
Burns to the body caused by hot surfaces.
WARNING!