3.6.1.8. Enabling Daylight Saving Time Compensation on the LTC Output
OUTPUT
LTC 1 OUTPUT
LTC 1 DST Enable
L1 dst enabled
L1 dst disabled
This menu item allows the user to control whether Daylight Saving Time
(DST) compensation will be applied to the time information on the LTC 1
output.
When set to
L1 dst disabled
, Daylight Saving Time compensation will not be
applied to the LTC 1 time information.
When set to
L1 dst enabled
the rules set by the
DST RULES
menu item on
the
GENERAL SETUP
menu will be used to adjust the LTC 1 time.
3.6.1.9. Enabling the LTC Output Parity Bit
OUTPUT
LTC 1 OUTPUT
LTC 1 Parity
L1 parity off
L1 parity on
This menu item allows the user to control whether parity bit is used on the
LTC 1 output.
When set to
L1 parity off,
the parity bit will always be set to 0.
When set to
L1 parity on,
the parity bit will be set to give an even number of
1’s in each LTC frame.
3.6.1.10. Enabling LTC Output Colour Frame Bit
OUTPUT
LTC 1 OUTPUT
LTC 1 Colr Frame
L1 cf off
L1 cf on
This menu item allows the user to control whether colour frame bit is used
on the LTC 1 output.
When set to
L1 parity off, the colour frame bit will always be set to 0
.
When set to
L1 parity on, the colour frame bit will be set to 1 to give indicate
colour frame synchronization
.
3.6.1.11. Setting The LTC Output Level
OUTPUT
LTC 1 OUTPUT
LTC 1 Level
L1 level = 30.4%
This menu item allows the user to adjust the LTC 1 output amplitude. The
value shown does not have any correspondence to a specific peak output
voltage. It only shows a percentage of output range. You will have to
measure the LTC1 output voltage and set this menu item to achieve the
desired output level
3.6.2. Configuring the Video Sync Outputs
There are two banks of three video sync outputs (for a total of six outputs) available on the 5600MSC.
The format of each output can be set independently of each other with the restriction that all outputs in
bank 1 (S1, S2, and S3) or bank 2 (S4, S5 S6) must be operating at the same clock frequency. For the
sake of simplicity only the menus for Sync Bank 1 will be described in the manual.
USO
RESTRITO
Содержание 5600MSC Series
Страница 2: ...USO RESTRITO ...
Страница 14: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...
Страница 41: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...
Страница 42: ...USO RESTRITO ...
Страница 114: ...USO RESTRITO ...
Страница 116: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...