Model 5600MSC Master Clock/SPG Manual
Page 4-6
Revision 1.6
TECHNICAL
DESCRIPTION
erase the software already present in the FLASH device. To proceed, press the
SELECT
key. The
front panel will show the message
UPGRADING IN 5 SEC
. This warning indicates that the unit will
be placed in programming mode in the time shown. Press the
ESC
key if you want to abort the
programming operation. When the timer expires the unit will be placed in programming mode and
its serial port is opened to communicate with the terminal software program. The front panel
display shows
UPGRADE MSC NOW
or
UPGRADE TG2 NOW
depending on whether you are
upgrading the main application firmware of the test generator firmware. Proceed to section 4.2.5 for
instructions on uploading the main application firmware using the terminal program. Proceed to
step 11 of section 4.2.4 for instructions on uploading the test generator firmware using the terminal
program.
4.2.4. Initiating Firmware Upgrade Mode From The Terminal Program
You may send commands to the 5600MSC Boot monitor in order to upgrade the 5600MSC application
firmware. The High definition Test generator can not be upgraded using the boot monitor method. To
initiate firmware uploading from a terminal program follow procedure described in steps 7 to 12.
7. Power up the 5600MSC Master Clock/SPG. After the unit powers up, a banner with the boot code
version information should appear in the terminal window. The cursor to the right of the word
“BOOT>” should be spinning.
For
example:
EVERTZ MFC5407 MONITOR 2.1.3
COPYRIGHT 1997, 1998, 1999, 2000, 2001 EVERTZ MICROSYSTEMS LTD.
COLD BOOT |
8. The following is a list of possible reasons for failed communications:
•
Defective Serial Upgrade cable.
•
Wrong communications port selected in the terminal program.
•
Improper port settings in the terminal program. (Refer to step 4 for settings). Note that
HyperTerminal will not change port settings while connected. Click on HyperTerminal’s
“Disconnect” Button then click the “Reconnect” button to activate changes to the port settings.
9. While the cursor is spinning press the <CTRL> and <X> keys, this should stop the cursor from
spinning. The spinning prompt will only remain for about 5 seconds. You must press <CTRL-X>
during this 5 second delay. If the unit continues to boot-up, simply cycle the power and repeat this
step.
10. Hit the <ENTER> key on your computer once.
11. Type the word “upgrade”, without quotes, and hit the <ENTER> key once.
12. The boot code will ask for confirmation. Type "y", without quotes.
4.2.5. Uploading the new firmware
13. You should now see a prompt asking you to upload the file.
USO
RESTRITO
Содержание 5600MSC Series
Страница 2: ...USO RESTRITO ...
Страница 14: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...
Страница 41: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...
Страница 42: ...USO RESTRITO ...
Страница 114: ...USO RESTRITO ...
Страница 116: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...