Model 5600MSC Master Clock/SPG Manual
Page 3-24
Revision 1.6
OPERATION
3.6.2.3.2.
Selecting the VITC Lines
OUTPUT
SYNC 1 OUTPUT
Sync 1 VITC Ln 1
S1 vitc ln 1= 14
OUTPUT
SYNC 1 OUTPUT
Sync 1 VITC Ln 2
S1 vitc ln 2= 14
These menu items select the lines on which the VITC will be inserted when
the
VITC enable
menu item is set to
VITC On
. The 5600MSC keeps track
of the lines for both the PAL and NTSC video standards, you will have to set
the line numbers separately for each video standard.
The default line values for NTSC-M are lines 14 and 16.
The default line values for PAL-B are lines 19 and 21.
This menu item is only applicable when the
Sync Standard
is set to the
PAL-B
or
NTSC-M
standards. The menu item will show the message
S1 no vitc in hd
when the
Sync Standard
is set to one of the high
definition video standards.
3.6.2.3.3.
Enabling Drop Frame Compensation on the VITC Output
OUTPUT
SYNC 1 OUTPUT
Sync 1 VITC DF
S1 vitc drop frm
S1 vitc non df
S1 no pal df
S1 no vitc in hd
This menu item allows the user to control whether drop frame counting
mode will be used for the Sync 1 output’s VITC time.
When the Sync 1 standard is set to
NTSC-M,
there are two counting modes
possible for the VITC time information. When set to
S1 vitc non df
, the Sync
1 output’s VITC time will count 30 frames per second, and the drop frame
flag of the VITC will not be set. When set to
S1 vitc drop frm
, the Sync 1
output’s VITC time will count in the SMPTE 12M Drop Frame mode,
dropping frame counts 0 and 1 of the first second of each minute except
minutes 0, 10, 20, 30, 40, and 50, and the drop frame flag of the VITC will
be set.
When the Sync 1 standard is set to
PAL-B,
the Sync 1 output’s VITC time
will count 25 frames per second, and the drop frame flag of the VITC will not
be set. The menu item will show the message
S1 no pal df
when the
Sync Standard
is set to
PAL-B
.
When the
Sync 1 Standard
is set to one of the high definition video
standards the menu item will show the message
S1 no vitc in hd
.
USO
RESTRITO
Содержание 5600MSC Series
Страница 2: ...USO RESTRITO ...
Страница 14: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...
Страница 41: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...
Страница 42: ...USO RESTRITO ...
Страница 114: ...USO RESTRITO ...
Страница 116: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...