Model 5600MSC Master Clock/SPG Manual
TECHNICAL DESCRIPTIONOPERATION
Revision 1.6
Page
3-45
3.6.7.8. Configuring the HD SDI Test Generator Colour Space
OUTPUT
HD TEST GEN
HTG Color Space
HTG space rgb
HTG space ycbcr
This menu item is used to select the colour space of the HD SDI Test
Generator when the
HTG Output Mode
is set to
4:4:4.
This menu item is
not applicable when the
HTG Output Mode
is set to
4:2:2.
When the menu item is set to the
HTG space rgb
, the
HD SDI TG OUT
outputs will contain the main channel (GB
(even)
R
(even)
) part of the test signal
and the
HD SDI BLACK
outputs will contain the Alpha channel
(AB
(
ODD
)
R
(odd)
) part of the test signal.
When the menu item is set to the
HTG space ycbcr
, the
HD SDI TG OUT
outputs will contain the main channel (YC
B
(even)
C
R
(even)
) part of the test
signal. The
HD SDI BLACK
outputs will contain the Alpha channel
(AB
(
ODD
)
R
(odd)
) part of the test signal.
3.6.7.9. Enabling the Closed Captioning Signal
This menu item is only available on units fitted with the 7751TG2-HD.
OUTPUT
HD TEST GEN
HTG Captioning
HTG caption off
HTG caption tst
HTG caption blk
HTG caption b&t
The
HTG Captioning
menu is used to enable the 608/708 closed captioning
data.
When the menu item is set to HTG caption off, no caption embedding takes
place.
When the menu item is set to the
HTG caption tst
, the
HD SDI TG OUT
outputs will contain the closed caption data.
When the menu item is set to the
HTG caption blk
, the
HD SDI BLACK
outputs will contain the closed caption data.
When the menu item is set to the
HTG caption b&t
, the
HD SDI TG OUT
outputs and the
HD SDI BLACK
outputs will contain the closed caption
data.
3.6.8. Selecting the HD SDI Video Test Generator Signal (HTG Option only)
OUTPUT
HD TEST SIGNALS
This menu item allows you to select the test signal on the HD SDI test signal
generator output.
Use the arrow keys (
Ï
,
Ð
) or turn the
SHAFT ENCODER
knob to select the
test signal. Table 3-6 shows the test signals that are available. Most of the
test signals are industry standard signals. Sections 3.6.8.1 to 3.6.8.3
describe the test signals that are unique to the 5600MSC. The name of the
current test signal is shown on the front panel display.
USO
RESTRITO
Содержание 5600MSC Series
Страница 2: ...USO RESTRITO ...
Страница 14: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...
Страница 41: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...
Страница 42: ...USO RESTRITO ...
Страница 114: ...USO RESTRITO ...
Страница 116: ...Model 5600MSC Master Clock SPG Manual Revision 1 6 This page left intentionally blank USO RESTRITO ...