TCP/IP Network Access Controller
15
3
Connection
3.1
Connecting to the Computer through the TCP/IP
User can carry out basic setting through the keypad on the EFC301F reader or connection
with the computer via TCP/IP. User can carry complicated system administration by
accessing the embedded system in the controller through various browsers.
3.2
Connecting to Power
You can power the controller through a specific PoE network switch by connecting a
network cable to the LAN port on the controller, or by connecting a 12 VDC power source to
the power port on the controller.
Figure 3-1 Connecting to power
Note:
1.
The voltage range of power source for EFC301F controller is 12 VDC
±
15%. The
maximum current of the controller is 600mA.
2.
The distance from the power supply to the controller should be within 2 meters. In
addition, the electromagnetic lock and alarm equipment must be powered separately
from the controller. The controller can only supply power for controller and readers.