TCP/IP Network Access Controller
35
4.7.1
Set Open Time
The door open time is the door open time after the valid card is swiped or the door open
button is pressed and the default value is 3 seconds. The maximum time set on the
controller is 999 min 59s. if the door open button is pressed, the door will open. The door
open time is started after the door open button is released. Scroll to the “Set Open Time ”
menu item and press “#” to enter its interface.
For setting the minutes, input three digits in the range of 0-999, and for setting seconds,
input two digits in the range of 0-59. Press “#” to confirm and the setting will take effect.
Press “*” to exit and the setting will not take effect.
4.7.2
Set Over Time
The door status switch is used to detect the open/closed status of the door. In general cases,
the door is closed. In case of door opening, the door should be closed after being opened
for a period of time, during which the controller may not receive the signal from the door
status switch. At the end of the door open time, if a door which should be closed is not
closed, timing will start and the recorded time is the Door Over Time. When the time has
exceeded, the controller will generate an alarm. The default Door Over Time is 10s.The
maximum Door Over Time set on the controller is 999 min 59s.
Scroll to “Set Over Time” menu item and press “#” to enter its interface.
For setting “minutes,” input three digits in the range of 0-999 and for setting “seconds,”
input two digits in the range of 0-59. Press “#” to confirm and the setting will take effect.
Press “*” to exit and the setting will not take effect.
Door Over Time
000 Min 10 Sec
Cancel
OK
Door Open Time
000 Min 03 Sec
Cancel
OK
Set Open Time
Set Over Time
Door Access Mode