TCP/IP Network Access Controller
82
Fire Alarm:
Indicates this is a fire alarm input.
Input Mode:
Select from Disabled, Normal Open or Normal Close.
Output Mode:
Select from Launch mode 1, Launch mode 2, Launch mode 1.2 or No output.
Alarm Duration:
Set up the duration time when an alarm has been triggered. Minimum
time is 5 sec.
Arm Delay:
The controller will be in the arm status after the setup time. Minimum time is 5
sec.
Action Doors:
This function will be enabled when the Fire Alarm is selected. Select Open
Door or Close Door.
Click the “Save” button to finish the operation.
11.1.1.2
Alarm Setting
In the alarm setting page, the user can configure whether the controller alarm output is
triggered in case of an event alarm of the controller and configure the alarm output time.
Figure 11-4 Alarm time
Select an Output Port and set up the alarm duration time. Click the “Save” button to finish
the operation.