9) Parameter group 200: Inverter control
E800 – Rev.01 -EN- SOFT Rev. 2.04
© 2015 EURADRIVES EUROPE GmbH
- 41 -
Two / Three wire control for START – STOP - Rotation:
This control mode overwrites the setting in F200, F201, F202
F208
Activation special
Two / Three wire control
Selection:
0: Deactivated
1:
Two-wire, Type 1 (static)
2:
Two-wire, Type 2 (static)
3:
Three wire, Typ1 (Impulse / pushbutton control – dynamic)
4:
Three wire, Typ2 (Impulse / pushbutton control – dynamic)
5:
Pulse / pushbutton control (dynamic)
Default
setting: 0
F208=0:
If Fixed-frequency control is required this mode must be deactivated!
If
F208>0:
functions
F200
,
F201
and
F202
are ignored.
“FWD”, “REV” and “X” are digital terminal input signals for two / three wire control mode. This logical signals are assigned to
OP1.....OP6 (OP8) through parameters F316....F323
Assigning-code for OPxx: FWD=
15
, REV=
16
, X=
17
– see chapter:
Parameter group 300 – Digital I/O configuration
F208=1
:
Two wire Type 1
Truth table
K1=START forward
(default on OP3)
K2=START reverse
(default on OP4)
F208=2
:
Two wire
Type 2
K1=START
(default on OP3)
Truth
table
K2=Rotating direction
(default on OP4)
F208=3
:
Three wire Typ 1
F208=4
:
Three wire Typ 2
F208=5
:
Three wire Typ 3
Pulse/pushbutton control:
FWD
(SB1) Impulse: START-forward / STOP
Toggle function
FWD=NO
REV
(SB2) Impulse: START-reverse / STOP
Toggle function
REV=NO
K1 K2
0 0 Stop
1 0
forward
0 1
reverse
1 1 Stop
K1
FWD
REV
K2
CM
K1
FWD
K1 K2
0 0
Stop
0 1
Stop
1 0
forward
1 1
reverse
REV
2
K
CM
SB3
SB2
SB1
X
REV
CM
FWD
CM
X
FWD
REV
K1
SB1
SB2
Pulse/pushbutton control:
Pulse/pushbutton control:
FW
D(SB2)=START-impulse
forward
FWD=NO
REV
(SB1)=START-impulse
reverse
REW=NO
X
(SB3)=cancel impulse (STOP)
X=NC
FWD
(SB1)=START-impulse
FWD
=NO
X
(SB2)=cancel-impulse (STOP)
X=NC
K1
=Direction
SB1
FWD
REV
REV
SB2
FWD
CM