9) Parameter group 200: Inverter control
E800 – Rev.01 -EN- SOFT Rev. 2.04
© 2015 EURADRIVES EUROPE GmbH
- 40 -
Kombinationsmöglichkeiten verschiedener Sollwertquellen
F204
F203
0 Internal
digital set with
memory t
1 External
Analogue
input AI1
2 Extern
Analogue
input AI2
4 Fix-
frequency
selection
5 PID
controller
6 Keypad
potentiom.
0 Internal
digital set
with memory
〇
●
●
●
●
〇
1 External
Analogue
input AI1
●
〇
●
●
●
〇
2 Extern
Analogue
input AI2
●
●
〇
●
●
〇
4 Fix-
frequency
selection
〇
●
●
●
●
〇
5 Internal
digital set
without
memory
●
●
●
●
●
〇
6 Keypad
potentiom.
●
●
●
●
〇
〇
9 PID
controller
●
●
●
●
●
●
●
: Allowed
〇
: Not allowed
The automatic cycling frequency control algorithm can not work in any combination with others