10
Kongsberg XP
10.15. Milling Unit Setup
Machine Connection
->
Machine Configuration
->
HW Configuration
->
Milling Unit setup
From the
Milling Unit setup
dialog, maintain the following parameters:
Specify Milling unit
If a milling unit is mounded, spedify milling unit type.
If no milling unit is mounted, select
None
.
COM-port
The physical COM-port used for communication with the control unit is specified.
Note:
The control unit needs to be connected to a genuine COM port. If connected to a USB-to-COM
adapter, the communication will fail.
These functions are used only after a hardware modification.
10.16. Conveyor Belt Control
Machine Connection
->
Machine Configuration
->
HW Configuration
->
Conveyor
Specify if the machine is equipped with
Conveyor Belt
.
10.16.1. Split Sheet Feed
Sheet in Load Position
Sheet Load, step 1
Sheet Load, step 2
In some occasions, the sheet unloaded from the cutting table can trigger the photo cell safety system.
To avoid this, the sheet feed movement is divided into two steps.