15
Kongsberg XE
Lag Setting
Lag
– lag value. This is the distance from the
rotation center to the back of the knife blade.
Enter the value as measured or as found using
the Lag test, see below.
Width
– knife bottom width
Enter the measured knife bottom width.
Lag Test
Run this wizard to obtain correct
Knife Lag
value.
Follow the instructions in the dialog.
Add the measured value to the displayed
value.