15
Kongsberg XE
From the
Adjust Selected Tool
– dialog, all
Tool Adjustment Wizards
are executed.
The following procedures are general descriptions of how to adjust the tools.
See the description of each
Tool Type
for more specific information:
We recommend using a sheet of
Folded Carton
material, 5-6 mm / 0.2 inch, when executing
the adjustments.
Note: All tools need to be adjusted in the position they will be used.
Before any adjustment, complete a
Table Top Reference
function.
Options
->
System Option
->
Table Setup
->
Table Top Reference
Main Menu->Machine->Table Top Reference
Machine Panel Toolbar
->
Table Top Reference
15.4 Lag Settings (for Rotating Tools)
1.
In the
Configure Tool dialog
, select the tool to be adjusted.
2.
Press the
Adjust Active Tool
button to enter the
Wizard
Selection dialog
.
3.
Select
Lag Settings
4.
Follow the instructions given to enter correct values.
5.
Repeat the procedure for all rotating tools.