S0740 800 196/E101019/P76
- 5 -
ca41_00
Design structure of the power source
The power source is transistor-controlled, operating on the inverter principle. It consists of a
number of function modules, as shown in the block diagram below. Each module has a
module number, which is always included as the first part of the name/identification of
components in the module.
The modules have the following main functions:
1 MMC module
The control panel and display.
2 Mains module
Mains interference suppressor, mains switch, auxiliary transformer.
10 TIG module
Comprises all TIG functions.
15 Power module
This module is a dual forward inverter, operating at a switching frequency of 2 x 40 kHz.
IGBT transistors are used as the switching elements. All power semiconductors are built
into modules.
20 Processor board module (controller module)
This is the controller board, 20AP1, with a microprocessor, that monitors and controls the
voltage and current.
Block diagram of the Mig 3001i.
Содержание Aristo Mig 3001i
Страница 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Страница 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Страница 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Страница 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Страница 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Страница 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Страница 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Страница 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Страница 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Страница 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...
Страница 75: ...S0740 800 196 E101019 P76 75 emptypage ...