S0740 800 196/E101019/P76
- 18 -
ca41_15_1
15 The power module
The power module converts the rectified 3-phase 400 V to the welding voltage. It consists of
a dual forward inverter, operating at a switching frequency of 2 x 40 kHz.
The mains rectifier bridge 2BR1, the IGBT modules IC3 and IC8 and the diode modules
15D1 and 15D2 are all mounted on a heat sink.
Schematic diagram of the power module
If circuit boards 15AP1 or 20AP1, are replaced, the gate pulse waveforms must be checked
afterwards and the machine must be soft-started. See page 50.
See the instructions on Page 54 concerning mounting of the components on the heat sink
(2BR1, 15AP1 with IC3 and IC8, 15D1 and 15D2).
WARNING!
The power module is at mains voltage.
0 V in the power module is connected to mains voltage.
Содержание Aristo Mig 3001i
Страница 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Страница 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Страница 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Страница 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Страница 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Страница 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Страница 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Страница 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Страница 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Страница 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...
Страница 75: ...S0740 800 196 E101019 P76 75 emptypage ...