S0740 800 196/E101019/P76
- 51 -
ca41f2soft
9.
Gate pulses from 20AP1.
S
Measure with the screen
(gnd) connected to +24 V.
S
The pulse frequency must be
40 kHz
1 kHz.
S
The pulse duration must be
41-44% of the cycle time,
measured at -10 V of the
negative pulse, as shown in
the graph to the right.
S
If there is an interruption in the connection to the
pulse transformer, the pulses are shaped as shown
in the graph to the left.
10. Gate pulses to the IGBTs.
S
Measure with the probe
connected to the gate.
S
The pulse frequency must be
40 kHz
1 kHz.
S
The pulse duration must be
40-44% of the cycle time,
measured at +5 V, as shown
in the graph to the right.
11. Primary side of the main
transformers
S
Measure with the probe
connected to DR1 and DR2
respectively.
S
The shape of the pulses
must be as in the graph to
the right.
Содержание Aristo Mig 3001i
Страница 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Страница 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Страница 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Страница 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Страница 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Страница 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Страница 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Страница 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Страница 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Страница 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...
Страница 75: ...S0740 800 196 E101019 P76 75 emptypage ...