S0740 800 196/E101019/P76
- 57 -
ca41f2calcur
Calibrating the current sensor signal
1.
Connect the power source to a resistive load.
2.
Connect a
calibrated shunt
in series with the load.
3.
Set the power source to MMA mode.
4.
Set a welding current of 100 A.
5.
Load the power source so that the voltage across the load is 24 V.
Circuit diagram for the current calibration
6.
Measure the shunt voltage using a
calibrated multimeter
.
7.
Using potentiometer R21 on circuit board 20AP1, adjust the shunt voltage to
correspond to 100 A
1 A.
Position of potentiometer R21 on circuit board 20AP1.
8.
Check the current at low values as well: 16 A at 19 - 22 V, for which the tolerance is
1 A. If the current is outside the tolerance, replace current sensor 15AP3.
Содержание Aristo Mig 3001i
Страница 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Страница 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Страница 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Страница 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Страница 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Страница 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Страница 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Страница 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Страница 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Страница 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...
Страница 75: ...S0740 800 196 E101019 P76 75 emptypage ...