S0740 800 196/E101019/P76
- 50 -
ca41f2soft
Soft starting
We recommend soft starting of the machine after replacing control circuit board 20AP1 or
circuit boards or components in the power module. This supplies the power module with a
low DC voltage in order to avoid injury to persons or damage to components.
It is also a good idea to use soft starting when fault tracing in the power module. In addition,
certain measurements in the machine should be made only during soft starting.
The following description refers to the use of soft starting tool SST 2.
Changing wire connections prior to soft starting
1.
Disconnect the machine from the mains supply
.
2.
Disconnect wires 1592 red (+) and 1591 black (-) from circuit board 15AP1.
3.
Insulate the wires from each other and from all other parts.
4.
Connect soft starting tool SST 2 to 20AP1 and 15AP1 as shown below. Connector C
must only be connected if there is an interuption in the temperature monitoring circuits.
SST 2 connected to 20AP1 and 15AP1
Measurements
The item numbers below refer to the circuit and component position diagrams on pages 52
and 53.
1.
Connect the machine to the mains and switch it on
.
2.
24 V AC from transformer 2TC1: must be 21 - 27 V
3.
+ 24 VA: must be 24 V
5%.
4.
+ 15 VA: must be 15 V
5%.
5.
+ 5.1 V, reference voltage for the over-/under voltage and temperature monitoring
circuits: must be 5.1 V
5%.
Set the machine to the MMA mode. The voltage levels given below are depending on the
input voltage from SST 2. If this voltage is higher or lower than in this description, the other
voltages will change correspondingly.
6.
Terminals CN09 1 and 2, intermediate voltage from SST 2: 23.4 V.
7.
Intermediate voltage after the charge resistors and the short-circuiting thyristor: 23.4 V
8.
The voltage across each one of the filter capacitors: 11.7 V. It is important that the
voltage is the same over both of the capacitors.
Содержание Aristo Mig 3001i
Страница 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Страница 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Страница 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Страница 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Страница 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Страница 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Страница 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Страница 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Страница 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Страница 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...
Страница 75: ...S0740 800 196 E101019 P76 75 emptypage ...