S0740 800 196/E101019/P76
- 65 -
ca41_test
Visual inspection
Disconnect the welding power source from the mains supply.
During visual inspection, each safety related function judged as relevant by the test
personnel, shall be checked for correct operation.
During visual inspection, the following listed items shall be checked:
1.
Torch/electrode holder, welding current return clamp.
S
missing or defective insulation
S
defective connections
S
defective, damaged switches
S
other damage
2.
Mains supply
S
defective, damaged cable
S
deformed, faulty plug
S
broken or thermally damaged plug pins
S
ineffective cable anchorage
S
cables and plugs unsuitable for the intended use and performance
3.
Welding circuit
S
defective damaged cable
S
deformed, faulty or thermally damaged coupler/sockets
S
ineffective cable anchorage
S
cables and coupler unsuitable for the intended use and performance
4.
Enclosure
S
missing or damaged parts
S
unauthorised modifications
S
cooling openings blocked or missing air filters
S
signs of overload and improper use
S
missing or defective protective covers (for example, gas cylinder holder)
S
missing or defective, lifting means, holder etc.
S
conductive objects placed in the enclosure
5.
Controls and indicators
S
defective switches, meters and lamps
S
incorrect fuses accesible from outside of the enclosure
6.
General condition
S
cooling liquid circuit leakage or incorrect cooling liquid level
S
defective gas hoses and connections
S
poor legibility of markings and labelling
S
other damage or signs of improper use
Содержание Aristo Mig 3001i
Страница 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Страница 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Страница 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Страница 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Страница 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Страница 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Страница 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Страница 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Страница 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Страница 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...
Страница 75: ...S0740 800 196 E101019 P76 75 emptypage ...