S0740 800 196/E101019/P76
- 30 -
ca41_20_1
One end of the CAN bus is in the power source and it must be fitted with a
terminating resistor, R28 in the circuit diagram on page 28. The terminating
resistor can be disconnected by removing the jumper from terminal D.
Terminal D, version 2 of 20AP1
Terminal D, version 1 of 20AP1
See page 61 for examples on how to connect the terminating resistors in
different equipment configurations.
20AP1:4
Temperature monitoring
Principle diagram of the temperature monitoring circuits
The temperature monitoring circuit operates when the temperature exceeds
110
_
C and resets at 50
_
C
NTC D1 and NTC D2 are fitted inside the diode modules D1 and D2.
NTC R28 is fitted on the cupper foil of circuit board 15AP2.
NTC IC3 and NTC IC8 are fitted inside the IGBT modules IC3 and IC8.
If the monitoring circuit operates, the power source is stopped and fault code 6
is displayed. The power source cannot be restarted until it has cooled
sufficiently.
Содержание Aristo Mig 3001i
Страница 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Страница 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Страница 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Страница 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Страница 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Страница 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Страница 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Страница 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Страница 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Страница 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...
Страница 75: ...S0740 800 196 E101019 P76 75 emptypage ...