S0740 800 196/E101019/P76
- 40 -
ca41f1
REMOTE CONTROLS
A number of remote control units can be connected to the power sources, these are
described in a separate service manual.
FAULT CODES
Fault codes are used in order to indicate and identify a fault in the equipment.
Fault log
All faults that occur when using the welding equipment are documented as error messages
in the fault log. When the fault log is full, the oldest message will automatically erase when
the next fault occurs.
Only the most recent fault message is displayed on the control panel. To read the entire
fault log, the power source must be connected to the ESAT: see service tools on page 45.
Faults are monitored/detected in two ways: by test routines that are run on initiation and by
functions that can detect a fault when it occurs.
The control panel displays a unit number to indicate which unit has generated the fault. The
following unit numbers are used:
U0
= welding data unit
U1
= cooling unit
U2
= power source
U3
= wire feed unit
U4
= remote control unit
Summary of fault codes
Fault
code
Description
Welding
data
unit
Power
source
Wire
feed
unit
Remote
control
unit
1
Memory error, EPROM
x
x
x
x
2
Memory error, RAM
x
x
x
3
Memory error, external RAM
x
x
4
+5 V power supply
x
x
5
Intermediate DC voltage outside limits
x
6
High temperature
x
8
Power supply 1
x
x
x
x
9
Power supply 2
x
x
x
10
Power supply 3
x
11
Wire feed speed
x
12
Communication error (warning)
x
x
x
x
14
Communication error (bus off)
x
15
Lost messages
x
x
x
x
16
High open-circuit voltage (VRD)
x
17
Lost contact with the wire feed unit
x
Содержание Aristo Mig 3001i
Страница 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Страница 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Страница 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Страница 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Страница 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Страница 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Страница 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Страница 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Страница 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Страница 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...