S0740 800 196/E101019/P76
- 59 -
ca41f2calarcv
1.
Welding with the filler wire positive: voltage sensing from the wire
This is the most common arrangement of arc voltage sensing.
V
= external voltmeter.
R
= load resistor.
The control panel must show the same voltage value as shown on the external
voltmeter
0.6 V. Adjust the display value by means of potentiometer R87.
2.
Welding with the filler wire negative: voltage sensing from the wire
V
= external voltmeter.
R
= load resistor.
The control panel must show the same voltage value as shown on the external
voltmeter
0.6 V. Adjust the display value by means of potentiometer R103.
3.
Welding with the filler wire positive or negative: no external sensing from the wire or
workpiece
V
= external voltmeter.
R
= load resistor.
The external voltmeter shows a value 0.2 - 1.6 V higher than the value shown on the
control panel. Do not adjust the value shown on the control panel: this is already
adjusted from 1) above.
Содержание Aristo Mig 3001i
Страница 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Страница 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Страница 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Страница 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Страница 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Страница 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Страница 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Страница 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Страница 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Страница 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...
Страница 75: ...S0740 800 196 E101019 P76 75 emptypage ...