3. Usage
56
Temperature Increasement Checking
Duration in Hot Water Mode
C4
40
1 - 20(in minutes)
Parameter No.
Meaning
Range
Default Value
Backup Heating Source For Hot
Water Mode
0(no), 1(yes)
C2
0
0
Priority Of Backup Heating Sources
For Hot Water Mode (Compared
With Unit Auxiliary Heater)
0(lower), 1(higher)
C3
And, as both "Backup Heating Sources For Hot Water Mode" and unit "Auxiliary Heater" can both be used as extal
heating source for hot water mode, the "Priority Of Backup Heating Sources For Hot Water Mode (Compared With Unit
Auxiliary Heater)" can be set, to choose "Backup Heating Sources For Hot Water Mode" or unit "Auxiliary Heater is
preferred to be activated first.
When:
Hot Water Temperature increasement in "Temperature Increasement Checking Duration in Hot Water Mode" is not
enough and actual water temperature is not over 58
℃
,
unit
will
activate
the
higher
priority
extra
heating
source
first
.
If
increasement
is
still
not
enough
,
unit
will
activate
the
lower
priority
extra
heating
source
also
.
If set and actual hot water temperature is over 58
℃
,
unit
will
activate
the
higher
priority
extra
heating
source
.
In
this
case
,
if
"
Backup
Heating
Source
For
Hot
Water
Mode
"
has
higher
priority
,
as
it
doesn
'
t
need
to
use
the
unit
water
circulation
,
heat
pump
unit
will
turn
to
heating
or
cooling
operation
to
maximum
the
usage
of
heat
pump
.
If there has a "Backup Heating Source For Hot Water Mode" connected, it can be put under the control of the unit by set
"Backup Heating Source For Hot Water Mode" to ON.
Parameter No.
Meaning
Range
Default Value
Maximum Allowable Set Water
Temperature in Heating Mode
0 (not exceeds compressor
maximum allowable water
temperature), 40 - 65
(maximum allowable set
water temperature in
heating mode)
C5
42
In heating mode, compressor can only work till maximum 58
℃
water
temperature
.
But
in
some
real
cold
days
,
this
temperature
may
still
not
enough
for
keep
heating
up
the
house
,
then
a
higher
allowable
temperature
can
be
set
here
,
to
the
unit
can
use
extra
heating
source
(
unit
Auxiliary
Heater
or
Back
Heating Source For
Heating Mode) to ensure the comfort of heating operation.
Note: This function should only be used if water temperature really need to be over 58
℃
to
heat
up
the
house
.
If
not
,
it
will
waste
energy
as
most
of
the
heating
may
carried
by
extra
heating
source
.
If floor heating is used as distribution system, please be sure the water flow into floor heating system not
exceed the maximum allowable water temperature for floor heating system, otherwise it may get damaged. It can be
controlled by set this parameter to a safety value, or add safety regulations at inlet of a floor heating system.
Parameter No.
Meaning
Range
Default Value
Manual ON/OFF of Heater in
Heating Mode
0
0(invalid), 1(valid)
C6
If heat pump unit meets a failure, extra heating source (unit "Auxiliary Heater" or "Backup Heating Source For Heating
Mode" can be manually switched ON for heating up the house by set "Manual ON/OFF of Heater in Heating Mode" to
ON.
Parameter No.
Meaning
Range
Default Value
Manual ON/OFF of Heater in Hot
Water Mode
C1
0
0(invalid), 1(valid)
If heat pump unit meets a failure, extra heating source (unit "Auxiliary Heater" or "Backup Heating Source For Hot Water
Mode" can be manually switched ON for heating up the shower water by set "Manual ON/OFF of Heater in Hot Water
Mode" to ON.
Содержание AWH11-V5+
Страница 2: ...2 ...
Страница 8: ...1 3 2 Monoblock unit 1 Before use 8 AW9 V5 AW11 V5 ...
Страница 75: ...Cable connected to fan motor capacitor 4 4 Maintenance 5 75 ...
Страница 79: ...5 1 Outlines and dimensions 5 Attached drawing Unit mm Indoor control unit 79 430 500 20 211 500 525 196 ...
Страница 80: ...5 Attached drawing Monoblock unit AW9 V5 80 157 95 60 317 156 1065 754 693 1053 343 354 50 ...
Страница 81: ...5 Attached drawing Monoblock unit AW11 V5 Unit mm 81 1204 1215 690 761 121 60 134 385 115 417 403 50 ...
Страница 85: ...5 Attached drawing Monoblock unit AWH9 11 V5 85 ...