3. Usage
41
【
】
Temperature Info
For example, if the setting is made like below:
Parameter No.
Meaning
Value
9
20 00
Normal Shower Time (for unit with
heat recovery function only)
Anti-legionella function
10
11
Parameter No.
Meaning
Range
Default Value
0
00 00
0(off), 1(on)
00 00-23 59
Anti-legionella function
Anti-legionella function starting time
Pump anti-block running time
12
Parameter No.
Meaning
Range
Default Value
00 00
00 00-23 59
Pump anti-block running time
Quiet operation
13
14
Parameter No.
Meaning
Range
Default Value
00 00
00 00
00 00-23 59
00 00-23 59
Quiet operation starting time
Quiet operation ending time
All temperature information of current running statue can be checked via operation panel in both ON/OFF status
.
Press and for 5 seconds
in main interface, to activate
inquiry of current running status.
Press or to check
all working status in sequence.
Number of
parameter
Value of
parameter
If at time 19:00 in the day, shower water is still not enough for shower, unit will activate standard hot water operation,
instead of using recovered heat to heat up the shower water.
Parameter 10 is used to activated or deactivate Anti-legionella function.
Parameter 11 is used to set the starting time of Anti-legionella function.
During the hot water operation, unit will record the highest hot water temperature it produced. If in 7*24 hours time
period, unit has not reached the set water temperature for "anti
-
legionella
function
" (
set
in
Advanced
Menu
)
even
once
,
then
unit
will
activate
anti
-
legionella
operation
at
"
Anti
--
legionella
function
starting
time
".
For details for "anti-legionella" function, please contact your installer or read chapter "Advanced Opeartion" in our manual.
Circulation water pump may easily get blocked if it has not working for long time. In order to avoide this from happening,
circulation water pump will be activated for 1 minute, if it is not working at this set clock time every day.
Thanks for the DC technology applied in this system, unit can lower both its compressor speed and fan rotating speed,
to get a ultra low noise operation in this set time period.
Содержание AWH11-V5+
Страница 2: ...2 ...
Страница 8: ...1 3 2 Monoblock unit 1 Before use 8 AW9 V5 AW11 V5 ...
Страница 75: ...Cable connected to fan motor capacitor 4 4 Maintenance 5 75 ...
Страница 79: ...5 1 Outlines and dimensions 5 Attached drawing Unit mm Indoor control unit 79 430 500 20 211 500 525 196 ...
Страница 80: ...5 Attached drawing Monoblock unit AW9 V5 80 157 95 60 317 156 1065 754 693 1053 343 354 50 ...
Страница 81: ...5 Attached drawing Monoblock unit AW11 V5 Unit mm 81 1204 1215 690 761 121 60 134 385 115 417 403 50 ...
Страница 85: ...5 Attached drawing Monoblock unit AWH9 11 V5 85 ...