3. Usage
30
Symbol
Function
Explanation
Compressor
indicator
Clock or parameter
indicator
Timer
Down value
Set button/Clock
UP value
Operation mode
selector
Timer button
Timer Shower
water
Timer
heating/cooling
ON/OFF
Working mode
1
2
Indicates the current working level,
“low range30-46”, "middle range47-65",
"high range66-100”
If symbol is "ON" compressor is working
Clock and parameter menu and group
indicator
Shows time when unit is "ON", Shows
parameter groupe or -number when unit
is "OFF" and parameter setting is selscted
Indicates that one or more operation timer
parameters is selected
When "ON" means unit is "OFF" until the
selected time where unit is set to be "ON"
Indicates that shower water is set to "Timer"
operation, and weather it is in "ON" periode
and if unit actually is working in this mode.
“1" shows that "Timer" for shower water
mode is selscted and that unit is within its
"ON" periode. "ON" indicates that unit is
actually working in shower water mode
Indicates that heating/cooling mode is set to
"Timer" operation, and weather it is in "ON"
periode and if unit actually is working in this
mode.
"2"shows that "Timer" for heating/
cooling mode is selscted and that unit is
within its "ON" periode. "OFF" indicates
that unit is not working in heating/cooling
mode at the moment
Button switch the entire unit on and off
Button a so have some parameter setting
functions
l
Button switch between basic operation
modes, Heating/cooling/shower/water, and
different combinations of these
Button
have some parameter setting
functions
also
Button increases set temperature, switch
between parameters or adjust set value in
parameter setting menu
Button
have some parameter setting
functions
also
Button deacreases set temperature, switch
between parameters or adjust set value in
parameter setting menu
Button
have some parameter setting
functions
also
Button activates the unit for changing in set
values in temperatures or parameters and
button enters clock setting when the unit “OFF”
Button
have some parameter setting
functions
also
timer settings
Button
have some parameter setting
functions
also
Содержание AWH11-V5+
Страница 2: ...2 ...
Страница 8: ...1 3 2 Monoblock unit 1 Before use 8 AW9 V5 AW11 V5 ...
Страница 75: ...Cable connected to fan motor capacitor 4 4 Maintenance 5 75 ...
Страница 79: ...5 1 Outlines and dimensions 5 Attached drawing Unit mm Indoor control unit 79 430 500 20 211 500 525 196 ...
Страница 80: ...5 Attached drawing Monoblock unit AW9 V5 80 157 95 60 317 156 1065 754 693 1053 343 354 50 ...
Страница 81: ...5 Attached drawing Monoblock unit AW11 V5 Unit mm 81 1204 1215 690 761 121 60 134 385 115 417 403 50 ...
Страница 85: ...5 Attached drawing Monoblock unit AWH9 11 V5 85 ...