3. Usage
40
5
5
6
6
7
7
8
8
Parameter No.
Parameter No.
Meaning
Meaning
Range
Default Value
Value
00 00
00 00
00 00
08 00
00 00
17 00
00 00
23 59
00 00-23 59
00 00-23 59
00 00-23 59
00 00-23 59
Heating/Cooling Timer ON-1
Heating/Cooling Timer ON-1
Heating/Cooling Timer OFF-1
Heating/Cooling Timer OFF-1
Heating/Cooling Timer ON-2
Heating/Cooling Timer ON-2
Heating/Cooling Timer OFF-2
Heating/Cooling Timer OFF-2
Then heat pump will only heat or cool the house during the period 00:00~08:00, and 17:00~23:59 every day.
1
2
When timer function is activated, following symbols might be shown on the screen:
This symbol means the unit
is in sanitary hot water Timer
ON period. Unit will work in
hot water mode when needed.
This symbol means the unit is
in cooling/heating Timer ON
period. Unit will work in
cooling/heating mode when
needed.
1
This symbol means the unit is
in sanitary hot water and
cooling/heating Timer ON
period. Unit will work for both
hot water and cooling/heating
mode (not in same time) when
needed.
This symbol means the unit is
neither in hot water nor
cooling/heating Timer ON period.
Unit will work not work for both
hot water and cooling/heating
mode even needed.
Normal Shower Time:
Parameter No.
Meaning
Range
Default Value
9
00 00
00 00-23 59
Normal Shower Time (for unit with
heat recovery function only)
Heating/Cooling Timer:
These parameters are used for setting the ON/OFF timer for heating or cooling operation. After setting, unit will only
activate heating or cooling operation, when needed, in the set timer period. For example, below setting is made
This parameter is designed for the unit with heat recovery function only. When using recovered heat to heat up sanitary
hot water, it is not always enough to heat up the shower water. If 1 hour before this "Normal Shower Time" set time is
reached, hot water temperature has still not reached the set value, unit will activate standard hot water operation to ensure
you can enjoy enough hot shower water at/after this time.
2
Содержание AWH11-V5+
Страница 2: ...2 ...
Страница 8: ...1 3 2 Monoblock unit 1 Before use 8 AW9 V5 AW11 V5 ...
Страница 75: ...Cable connected to fan motor capacitor 4 4 Maintenance 5 75 ...
Страница 79: ...5 1 Outlines and dimensions 5 Attached drawing Unit mm Indoor control unit 79 430 500 20 211 500 525 196 ...
Страница 80: ...5 Attached drawing Monoblock unit AW9 V5 80 157 95 60 317 156 1065 754 693 1053 343 354 50 ...
Страница 81: ...5 Attached drawing Monoblock unit AW11 V5 Unit mm 81 1204 1215 690 761 121 60 134 385 115 417 403 50 ...
Страница 85: ...5 Attached drawing Monoblock unit AWH9 11 V5 85 ...